Thetford Cassette C2 Repair Manual page 18

Hide thumbs Also See for Cassette C2:
Table of Contents

Advertisement

*Underneath instructions only have to be followed if the Cassette toilet has been produced before
November 1992 (see identification label). As otherwise water will stay in during winterizing,
the pump will be moved to the left side of the level indicator (from A to B).
The distance from A to B will be around 10cm. Outside view
Take tissue well and
tissue holder out to
H.
get to the location of
the pump.
Unscrew the screw
I.
on the pump retainer
and take complete pump
out of the water tank.
J.
4.
Place the linkage above the pump retainer
and screw the two together from the
K.
underside upwards with screw nr.5.
Note: make sure that the linkage is
placed on the pump retainer as
positioned on the photo with nr.4 (J).
Connect flush tube back onto
L.
the pump and place the pump
on the left side of the level
indicator and screw the linkage
on the place where the pump
was assembled in the first
place. Screw nr. 3 has to be used.
Place tissue holder and
M.
tissue well back into
the water tank.
Tissue well
5.
3.
Nr. 3 (screw) and 4 (linkage) are in the package.
Nr. 5 is the screw from the pump (see I, photo 1).
Tissue holder
Pump retainer
**As the screwing may need some force,
be careful for injuries on hands and
fingers.
Disconnect the
flush tube from
the pump.
B.
A.
17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cassette c4Cassette c200Cassette c400

Table of Contents