Product Storage Temperature; Temperature Setting For The Useful Volume Of The Refrigerated Display Cabinets; Defrost Mode - UBC ZEUS Operating Manual

Table of Contents

Advertisement

Available languages

Available languages

  • ENGLISH, page 33
A current temperature inside the useful volume is shown on the controller display. The procedure for changing the
useful volume temperature is described in p. 10. Reading of the temperature sensor is adjusted in programming mode
exclusively by the service provider's personnel.
The useful volume temperature is set in terms of temperature conditions according to the requirements of the
product storage technology and recommendations on the package.
10. TEMPERATURE SETTING FOR THE USEFUL VOLUME OF THE REFRIGERATED
The temperature in a cinnamon base can be set to the controller in program mode. In the case of a victorist on the
control of the controller, it's described in detail in the doodatka.
Programm electronic controllers DANFOSS ERC 213 for refrigeration vitrin.
On the face of the controller panel є display and three buttons control buttons (see Figure 2.)
For temperature, temperature in a cinnamon base should touch the button 1. On the screen you see the numbers (for
example, -18.0), the temperature is set at the same time as when the speed is cooled down.
Used button 3 or 4, the new value will be set to new temperatures (for example, -22.0). For this residual installation,
short-term onset is 1.
Now the temperature will be at a temperature of minus 22 ° C.
The refrigerated display cabinets has an electronic thermostat with an automatic defrost system.
The defrosting time and time interval between the defrost cycles is changed by the service provider's personnel.
ATTENTION! When setting the time interval between the defrost cycles, the controller system settings are avail-
able that determine the operation of the refrigerated display cabinets. Make sure that their values have not changed.
To change the time interval between two defrost cycles enter the controller menu. Press and hold button 1, after a
few seconds the display shows in which you must enter the password code using buttons 3 and 4 (the password code is
available only to the service department). Next, using the menu, find the parameter "d03", use buttons 3 and 4 to set the
required defrost interval, for example, to save the values, press button 1.
To manually activate the defrost, press button 4 once. If there are conditions for defrost, the defrost will turn on, and
the defrost LED will light up.
ATTENTION! Generally, the refrigerated display cabinets is manually defrosted when a large snow cover is
formed on the evaporator due to a wrong choice of the automatic defrost cycle.

9. PRODUCT STORAGE TEMPERATURE

DISPLAY CASE
Fig. 5 – Electronic controller DANFOSS ERC 213

11. DEFROST MODE

42
ZEUS
www.beer-co.com

Advertisement

Table of Contents
loading

Table of Contents