Haier T-Series Service Manual page 34

Wall mounted type dc inverter air conditioner
Table of Contents

Advertisement

Indoor and
E7
Outdoor
E1
Indoor
E2
Malfunction
E4
E14
F12
F1
Outdoor
F22
Malfunction
F3
F19
F4
F21
F7
F6
F25
F11
F28
F2
F23
10.3.1 Thermistor or Related Abnormality
outdoor display
LED1 flash 10 times:Defrost temperature sensor failure
LED1 flash 11 times:Suction temperature sensor failure
LED1 flash 12 times:Ambient temperature sensor failure
LED1 flash 13 times:Discharge temperature sensor failure
Method of
The temperatures detected by the thermistors are used to determine thermistor errors
Malfunction
Detection
Malfunction
when the thermistor input is more than 4.92V or less than 0.08V during compressor
D
e
c
s i
o i
n
o
p
r e
t a
Conditions
Note: The values vary slightly in some models
Supposed
■ Faulty connector connection
Causes
■ Faulty thermistor
■ Faulty PCB
Troubleshooting
* Caution Be sure to turn off power switch before connect or disconnect connector, or else
■ ■ ★
★ ■ ■
★ □ □
★ □ ★
■ □ ★
■ ★ ■
□ ★ ★
★ ★ ■
■ ★ ■
■ ★ □
■ ★ ■
□ □ ★
■ ★ ■
□ ★ ■
★ □ ■
■ ★ ■
■ ★ ■
■ ★ □
■ ★ □
o i
. n
parts damage may be occurred.
Communication fault between indoor
15
and outdoor units
--
Room temperature sensor failure
--
Heat-exchange sensor failure
--
Indoor EEPROM error
--
Indoor fan motor malfunction
1
Outdoor EEPROM error
2
The protection of IPM
Overcurrent
3
electricity for the outdoor model
Communication fault between the IPM
4
and outdoor PCB
6
Power voltage is too high or low
Overheat
8
temperature
10
Defrost temperature sensor failure
11
Suction temperature sensor failure
12
Ambient temperature sensor failure
13
Discharge temperature sensor failure
deviate from the normal
18
compressor
19
Loop of the station detect error
24
Overcurrent of the compressor
Overcurrent protection for single-phase
25
of the compressor
33
Connector Wiring Diagram
protection
of
protection
for
Discharge
for the
Domestic Air Conditioner
AC

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1u26ba1era

Table of Contents