VERIPOS LD6 Quick guide
VOSS:
http://help.veripos.com
Download a Service Notification Form from
http://help.veripos.com
contacting the Veripos Helpdesk for an enable access code. Provide details requested
and the type of Service(s) you require, e.g. Veripos Ultra with Standard.
Tel. +44 1224 965900
email:
helpdesk@veripos.com
Connecting data outputs from the LD6
Position data is output from the LD6 from the RJ45 serial ports or the 2 LAN Port(s).
Go to Home / Settings / I/O and use the Arrow buttons to select and note the COM
port no. required. Refer to the default COM port settings below and in the LD6
Operation Manual. Select the data parameters required including protocol and baud
rate. Touch the Finish button when completed.
1.
LD6 Internal Solution output
2.
LD6 with Verify QC - LAN Solution output (Recommended)
Configure LAN working with Verify QC PC (Windows 7)
On the PC go to Control Panel/Network and Sharing Settings.
Click on Change Adapter Settings then right-click on the Local Area Connection and
click Properties.
AB-V-MA-00535_Rev L3
In "This connection uses the following items:" window scroll to highlight Internet
and use this when
Protocol Version 4 (TCP/IPv4) and click Properties.
Select the radio button "Use the following IP address:" and enter 192.168.2.4 (or
192.168.3.4 if using LAN2)
Now enter in the "Default gateway" the IP address of the LD6 Ethernet port used;
Upper LAN port address is 192.168.2.2. Lower LAN port address is 192.168.3.3.
Click OK to accept.
For Win XP, go to Control Panel/Network Connections to set IP.
Configure Verify QC for Client Sockets with the following LAN ports;
Default output data stream
3.
LD6 with Verify QC - Serial Port Solution output (Optional)
The LD6 is capable of running the Verify-QC software onboard the receiver, thus
removing the requirement for a separate Verify-QC PC. Refer to the LD6 Operations
manual for further information.
LD6 LAN Port mapping
Port No
RTCMa
9001
GNSS RAW
9012
Option – MF RTCM
9031
Option – UHF RTCM
9051
Serial ports
Use the default COM port table below when making connections to ships systems.
You can view or amend baud rates, etc. by navigating to Settings/I/O and use the
onscreen controls.
COM port
Source /Baud
Content
No.
COM1
LBand / 9600
RTCMa
COM3
GNSS1 / 115200
Raw
COM4
LBand / 9600
RTCMb
COM6
MF
/ 4800*
RTCM
COM7
UHF
/ 38400*
RTCM
Other COM ports (COM9 and above) are available for configuration by user.
Serial Data cable pin out
Launch Orion DP software
Where this software is installed on the LD6, attach a touchscreen monitor to the VGA
port and plug in the USB connection.
Power cycle the LD6 for the screen to be recognized, then go to Actions/ Calibrate
screen for 1 & 2 then Launch Orion.
Note: After connecting a VGA monitor, Screen 1 (LD6 screen) may require to be
calibrated. If so, select 'Calibrate Screen 1' and follow on-screen prompts.
Shut Down
To shut down the LD6 go to Actions/Shutdown/Yes and allow to power down.
Once completed switch off using the front panel switch.
Data format
232
232
232
232
232