OWNER'S MANUAL Amazon Unitario Descarga vertical K2UF-280 DN3 K2UF-400 DN3 K2UF-335 DN3 K2UF-450 DN3 Original instructions Thank you very much for purchasing our air conditioner, Before using your air conditioner, please read this manual carefully and keep it for future reference.
Never inspect or service the unit by yourself. CONTENTS PAGE Ask a qualified service person to perform this work. IMPORTANT SAFETY INFORMATION ............1 Do not dispose this product as unsorted municipal waste. PARTS NAMES...................2 Collection of such waste separately for special treatment is necessary.
In order to avoid electric shock or fire, make sure that an 2. PARTS NAMES earth leak detector is installed. Be sure the air conditioner is grounded. In order to avoid electric shock, make sure that the unit is grounded and that the earth wire is not connected to gas or water pipe, lightning conductor or telephone earth wire.
3. When the Priority Mode has been set, the first indoor unit will Protection Device work in Heating Mode that is Heating Priority, please refer to the This protection device will stop the unit automatically in case ITEM 1 for the control logic. If the first indoor unit is work in the air conditioner is on forced running mode.
Page 6
Please read the following illustration (before apply for Table.4-1 servicing) Troubles Causes Outdoor unit FAN function stops automatically to defrost. It White mist or water is the start and stop sound of the solenoid valve The sound of “hiss” At the beginning and the end of the running process, sounds like water flow in valve occurs, which will be amplified in 3~15 minutes, this is caused by dehumidifying process of refrigerant...
5. MALFUNCTION Malfunction display of outdoor unit’s DSP1 Table.5-1 Error code Error or protection type Note Outdoor units communication error Only display in slave unit Phase sequence error Indoor units and master unit communication error Reserve The pipe temp. sensor (for sensing the ambient temp) error Reserve Reserve Outdoor unit address error...
6. CONSTRAINT COOLING AND QUERY MAIN BOARD (OUTDOOR UNIT) Query button Constraint Cooling Once pressing the constraint cooling button (see the chart on Constraint cooling button the right), all the indoor unit will be on forced cooling mode and the wind speed is HIGH. COOL CHECK Fig.6-1...
2) This table is appropriate for the models with only one inverter compressor. Table 6-2 Normal display Display content Note Outdoor unit address Outdoor unit capacity 8, 10 Modular outdoor unit qty. Available for master unit Outdoor unit total capacity Capacity requirement Indoor unit total capacity requirement Available for master unit...