Cable over sink installation
Position the appliance upright with plumbing connections facing down.
1. Line up the Fixture disk and rubber pad. (Fig. 1)
2. Feed the faucet's water pipe through the hole. (Fig. 2)
3. Line up the rubber pad and pedestal. (Fig. 3)
4. Feed the mounting element. (Fig. 4)
Make sure the mounting elements are aligned.
Then tighten the mounting nut and make sure the faucet is secure.
1
5. Plumbing installation:
Using the water inlet hose supplied in the HOTAP package
(RECOMMENDED).
This hose has an NPT ½" fitting at one end for connecting
to the water supply, and a BSP ½" fitting at the other end for
connecting to the HOTAP pipe.
L1
N
G
Note the colors of the fittings: The gasket in the BSP fittings is
black, while the gasket in the NPT fitting is white.
12/2 AWG
6. Connect the hose to the pipe.
7. Turn on the water supply line. Then turn the faucet handle,
and test the water supply for adequate flow and leaks. If no
leaks are present, you can proceed to electrical installation.
8. Make sure the faucet handle is in the OFF position.
Model HOTAP 3kW
Connect the wires in the faucet's power cable directly to
a dedicated circuit breaker on the main electrical panel,
according to the electrical diagram shown here.(Fig. 8a)
10
2
2
3
3
a)
5
NPT 1/2"
NPT 1/2"
8a
G
4
4
BSP 1/2"
BSP 1/2"
L1
N
12/2 AWG
b)
NPT 1/2"
NPT 1/2"

Advertisement