Replace Malfunctioning PSU

If a PSU or its fan malfunctions, please see the instructions below to replace
the malfunctioning PSU.
1 Unplug the power cord from the PSU to be replaced.
By pressing the Beep Off button, you can silence the long beeping sound
Note:
when you hear it.
2 Push the lever of the PSU at the back panel in the indicated direction.
3 Pull out the PSU from the expansion unit.
4 Prepare a new PSU, and push it back to the slot until you hear a click.

Replace Malfunctioning SAS Module / Fan

If a SAS module or its fan malfunctions, please see the instructions below
to pull out the expansion unit SAS module and replace the module or the
malfunctioning fan.