OPERATION

GENERATOR LOCATION

Read and understand all safety information before starting
the generator.
NEVER operate the generator inside any building, including
garages, basements, crawlspaces, sheds, enclosure, or
compartment, including the generator compartment of a
recreational vehicle.
Electrocution hazard. Never use the generator in a
location that is wet or damp. Never expose the generator
to rain, snow, water spray, or standing water while in
use. Protect the generator from all hazardous weather
conditions. Moisture or ice can cause a short circuit
or other malfunction in the electrical circuit. Using a
generator or electrical appliance in wet conditions, such
as rain or snow, or near a pool or sprinkler system, or
when your hands are wet, could result in electrocution
Fire hazard. Only operate the generator on a solid, level
surface. Operating the generator on a surface with loose
material such as sand or grass clippings can cause debris
to be ingested by the generator that could block cooling
vents or the air intake system. Allow the generator to
cool for 30 minutes before transport or storage.
The generator should be on a flat, level surface at all times
(Even while not in operation). The generator must have
at least 5 ft. (1.5 m) of clearance from all combustible
material.
Do not operate the generator in the back of a SUV, camper,
trailer, truck bed (regular, flat, or otherwise), under stairs,
next to walls or buildings, or in any other location that will
not allow for adequate cooling of the generator and/or the
muffler. DO NOT contain generators during operation.
OPERATION
Asphyxiation hazard. Place the generator in a well-
ventilated area. DO NOT place the generator near vents
or intakes where exhaust fumes could be drawn into
occupied or confined spaces. Carefully consider wind
and air currents when positioning the generator.
GROUNDING
Shock hazard. Failure to properly ground the generator
can result in electric shock.
Only use grounded 3-prong extension cords, tools, and
appliances, or double-insulated tools and appliances.
The generator neutral is floating. The generator ground
terminal is connected to the frame of the generator, the
metal non-current-carrying parts of the generator, and
the ground terminals of each receptacle. The generator
(stator winding) is isolated from the frame and from the
AC receptacle ground pin. Electrical devices that require
a grounded receptacle pin connection may not function
properly.
If this generator will be used only with cord and plug
equipment connected to the receptacles mounted on the
generator, National Electric Code does not require that
the unit be grounded. However, other methods of using
the generator may require grounding to reduce the risk of
shock or electrocution.
Before using the ground terminal, consult a qualified
electrician, electrical inspector, or local agency having
jurisdiction for local codes or ordinances that apply to the
intended use of the generator.

HIGH ALTITUDE OPERATION

Engine power is reduced the higher you operate above sea
level. Output will be reduced approximately 3.5% for every
1000 feet of increased altitude from sea level.
High altitude adjustment is required for operation at
altitudes over 5,000 ft. (1524 m). Operation without this
adjustment will cause decreased performance, increased
fuel consumption, and increased emissions.
DO NOT operate the generator at altitudes below 2,000 ft.
(762 m) with the high altitude kit installed. Engine damage
may occur.
High Altitude Carburetor Kit Part# 202801