Two features have been added to the TRMIM-10R and TRMIM-20R.
The units now have autowrap capability and a BYP LED on the front
panel. This addendum describes these changes.

AUTOWRAP CAPABILITY

The TRMIM-10R and TRMIM-20R now have autowrap capability. This
addendum supplements Chapter 3 (Installation) of the manual. All
references to wrap jumpers are no long applicable.
The RI/RO LEDs on the front panel are now two color. They display
green when the port is not wrapped and display red when the port is
wrapped. If the light is off, the port has been disabled by network
management.
TRMIM-10R
SN
7
RI
R O
TOKEN RING
9030609-01 September 1992

ADDENDUM SHEET

BYP
16Mb
1
5
6
Ring-in/Ring-out LEDs
Ring-in / Ring-out
(green non-wrap, red wrap, off disabled)
TRMIM-20R
SN
BYP
16Mb
7
1
A
A
T
T
8
2
T
T
A
A
9
3
C
C
10
4
H
H
E
E
R I
5
D
D
RO
6
1
7
X
X
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TRMIM-10R and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Enterasys TRMIM-10R

  • Page 1 Two features have been added to the TRMIM-10R and TRMIM-20R. The units now have autowrap capability and a BYP LED on the front panel. This addendum describes these changes. AUTOWRAP CAPABILITY The TRMIM-10R and TRMIM-20R now have autowrap capability. This addendum supplements Chapter 3 (Installation) of the manual.
  • Page 2 ADDENDUM Switches have been added to the board as shown in the figure below. The switches are configured as follows: Switch 1 Switch 2 Modules are shipped with switches 1 and 2 turned on. Switches 3 and 4 are not used. NOTE: Autowrap must be disabled when the respective ring port is attached to a device that is not capable of autowrap (i.e., TRC-800).
  • Page 3 BYP LED The TRMIM-10R and TRMIM-20R now have a BYP LED on the front panel as shown below. All references in the manual to the ERR LED are no long applicable. The BYP LED indicates the module is in Bypass mode. When lit, this indicates the module has been bypassed through system management.

This manual is also suitable for:

Trmim-20r

Table of Contents