Viessmann VITOTROL 100 Operating Instructions For The System User page 15

Room temperature controller
Table of Contents

Advertisement

Setting a permanent room temperature
Example:
In "Prog. 3", you only want to enable 3
time phases. "Comfort" from 06:00 h to
10:00 h; "Eco" from 10:00 h to 22:00 h;
and "Reduced" from 22:00 h to 06:00
h.
Select "Time ph. 1", "Time ph. 2" and
"Time ph. 6".
Time phases 3, 4 and 5 are automatically
disabled.
For every enabled time phase, the fol-
lowing must be entered:
■ Start time
■ Stop time
■ Temperature ("Comfort", "Eco",
"Reduced")
You can select time phases for several
days (day groups) or for individual days:
■ "MO–SU" for the same time phases
every day of the week
■ "MO–FR" for the same time phases
Monday to Friday
■ "SA–SU" for the same time phases on
Saturday and Sunday
■ "SINGLE DAY" different time phases
for individual days
Note
Settings for individual days take prior-
ity over settings for several days.
01. Open the flap.
02. Press
twice.
03. With / select "Settings".
04. Confirm with OK.
05. With / select "Programs".
(cont.)
06. Confirm with OK.
07. Select the program you want to
change with / (e.g. "Prog 1").
08. Confirm with OK.
09. Select "Heating circuit" with / .
10. Confirm with OK.
11. With / select "Set".
12. Confirm with OK.
13. Set the required group of days/indi-
vidual day with / .
14. Confirm with OK.
15. Set the required time phase or ini-
tially the required day with / .
16. Confirm with OK.
17. With / set the required start time,
stop time and the temperature, one
after the other (e.g."Reduced").
18. Confirm respectively with OK.
19. Proceed as described in points 15 to
18 to set further time phases.
Note
Should gaps be created between
the time phases, these are closed
automatically by extending the pre-
vious time phase.
Central heating
15