INSTALLER SETUP MENU
Settings
This setting will flash FILT in the
Filter
display after the elapsed run time
Change
to remind the user to change the
filter. The OFF setting will disable
Reminder
this feature.
This setting allows the installer to
Room
change the calibration of the room
Temperature
temperature display so that, for
example, the thermostat would
Calibration
read 72°F instead of 70°F.
The installer can select the
Minimum
minimum run time for the
Compressor
compressor to help protect the
On-Time
compressor from short-cycling.
12
Display
Adjustment Options Default
The filter change reminder
Next step
can be adjusted from OFF
to 2000 hours in 50 hour
increments. Press the second
button from the top left side of
the thermostat to display the
Prev step
current filter elapsed runtime.
Next step
The room temperature display
can be adjusted to read up to
3° above or below the factory
calibrated temperature.
Prev step
The minimum compressor run
time can be adjusted from OFF
Next step
to 3, 4, or 5 minutes. If 3, 4, or
5 is selected, the compressor
will run for at least the
selected time before turning off
Prev step
(although the fan may continue
to run for a short time).
OFF
0
OFF