SERVICE & OPERATING MANUAL
ORIGINAL INSTRUCTIONS
2" Elima-Matic Bolted Flap Pump
with Plastic Center Section
E2 Plastic Pumps
• Polypropylene

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the E2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Versamatic E2

  • Page 1 SERVICE & OPERATING MANUAL ORIGINAL INSTRUCTIONS 2" Elima-Matic Bolted Flap Pump with Plastic Center Section E2 Plastic Pumps • Polypropylene...
  • Page 2: Safety Information

    The use of non-OEM replacement parts will void (or negate) agency certifications, including CE, ATEX, CSA, 3A and EC1935 compliance (Food Contact Materials). Warren Rupp, Inc. cannot ensure nor warrant non-OEM parts to meet the stringent requirements of the certifying agencies. • Model E2 Bolted Plastic Flap...
  • Page 3 • EU Declaration of Conformity - ATEX Directive 4 EPDM N NPT Tapered Thread 7 Hytrel Design Level *More than one option may be specified for a particular pump model. • Model E2 Bolted Plastic Flap Model E2 Bolted Plastic Flap •...
  • Page 4 Materials E2 Plastic 2" Bolted Flap Pump Flow Rate Performance based on the following: elastomer fitted pump, flooded suction, water at ambient conditions. The use of other materials and varying hydraulic conditions may result in deviations in excess of 5%.
  • Page 5: Dimensional Drawings

    Dimensional Drawings Dimensional Drawings E2 Plastic Bolted Flap - Flanged Manifold E2 Plastic Bolted Flap Non-Metallic Dimensions in Inches [ ] in Millimeters. Dimensional tolerance: +/- 1/8" [ ] +/- 3mm Dimensions in inches (metric dimensions in brackets) The dimensions on this drawing are for reference only. A certified drawing can be requested if physical dimensions are needed.
  • Page 6: Principle Of Pump Operation

    The discharged and primed liquid’s of the main directional air valve, redirecting the compressed air to the directions are controlled by the check valves (ball or flap) orientation. opposite inner chamber. ⑥ Model E2 Bolted Plastic Flap •...
  • Page 7: Troubleshooting Guide

    Entrained air or vapor lock in chamber(s). Purge chambers through tapped chamber vent plugs. flow ratio. For additional troubleshooting tips contact After Sales Support at service.warrenrupp@idexcorp.com or 419-524-8388 • Model E2 Bolted Plastic Flap Model E2 Bolted Plastic Flap •...
  • Page 8: Composite Repair Parts Drawing

    Ring Sealing, Fluorocarbon FKM **Air End Kit does not include entire air valves assembly. It includes 675.073.364 Ring Sealing, EPDM replacement sleeve and spool set, plus o-rings. 675.073.365 Ring Sealing, Neoprene • Model E2 Bolted Plastic Flap Model E2 Bolted Plastic Flap •...
  • Page 9: Composite Repair Parts List

    ROTATION **Air End Kit does not include entire air valves assembly. It includes 675.073.364 Ring Sealing, EPDM replacement sleeve and spool set, plus o-rings. 675.073.365 Ring Sealing, Neoprene • Model E2 Bolted Plastic Flap Model E2 Bolted Plastic Flap •...
  • Page 10 For Model E2PP7X7S9A-F-XXX Hytrel Diaphragms, Flap Valves, Neoprene Hinge Pads, Seals, Wear Pads and Sealing Rings 476.V354.677 Wetted End Kit For Model E2PP6X4S9A-F-XXX Santoprene Diaphragms, EPDM Flap Valves, Hinge Pads, Seals,Wear Pads and Seals • Model E2 Bolted Plastic Flap...
  • Page 11: Material Codes

    The recyclability of Color coded: YELLOW 666..FDA Nitrile Diaphragm, Versamatic products is a vital part of Warren Rupp’s Read these instructions completely, before installation PTFE Overlay, Balls, and Seals commitment to environmental stewardship.
  • Page 12: Pilot Valve Assembly

    Step 6: Reassemble in reverse order. Step 7: Remove seal, diaphragm rod (42). Step 8: Clean seal area, lightly lubricate and install new seal, diaphragm rod (40, not shown). • Model E2 Bolted Plastic Flap Model E2 Bolted Plastic Flap •...
  • Page 13: Diaphragm Service Drawing, Non-Overlay

    Failure to comply with rod. Align diaphragm through bolt holes, always going the recommendations stated in this manual will damage the pump, and void factory warranty. • Model E2 Bolted Plastic Flap Model E2 Bolted Plastic Flap •...
  • Page 14: Declaration Of Conformity

    Versamatic warrants to the original end-use purchaser that no product sold by Versamatic that bears a Versamatic brand shall fail under normal use and service due to a defect in material or workmanship within five years from the date of shipment from Versamatic’s factory.