Specification
Rated voltage
Rated frequency
Rated current
Power consumption – electronics
Power consumption
Permissible ambient temperature
Operation
■
Storage and transport
■
Rated relay output breaking capacity
P1 (solar circuit pump)
■
P3 (transfer pump)
■
Connection and wiring diagram
Fig. 11
Plug 230 V~
Solar circuit pump (only with PWM control)
P1
sF
P3
Transfer pump
fH
Power supply
fÖ
A
Power supply for accessories
fÖ
230 V∼
50 Hz
2 A
2 W
9 mA
0 to +40 °C
20 to +65 °C
–
1 A 230 V~
1 A 230 V~
Extra low voltage connections
PWM1 Speed control, solar circuit pump
TS1
Cylinder temperature sensor NTC 10 k
%
TS2
Collector temperature sensor NTC 20 k
&
TS3
No function
PlusBus
jF
Specification
Ω
Ω
19