System Requirements; Preparing For Installation; Heating System - Viessmann Vitoconnect 100 Installation And Service Instructions For Contractors

Communication interface for remote monitoring and control of heating systems via the internet, for the following user interfaces: - vicare app - vitotrol plus app - vitoguide
Table of Contents

Advertisement

System requirements

Heating system

The Vitoconnect 100, type OPTO1 can be used for a
single boiler system with Vitotronic control unit, without
heating circuits downstream.
Supported control units
The Vitoconnect 100, type OPTO1, can be used in
conjunction with the following Viessmann control units.
Heat source
Wall mounted or storage
combi boilers
Supported control units
Vitotronic 200, type
HO1
HO1A
HO1B
HO1D
HO2B
Vitotronic 200-RF, type
HO1C
HO1E
Note
For an up to date overview of the supported control
units see www.viessmann.com/vitoconnect.
IP network
System requirements
WLAN router with activated WLAN. The WLAN
router of the system user must be protected by a suf-
ficiently secure WPA2 password. We advise against
unencrypted connection of the Vitoconnect 100 to a
WLAN router.
Internet connection with "flat rate" (tariff independ-
ent of time and data volume) and high availability,
i.e. the Vitoconnect 100 is permanently linked to the
Viessmann server.
Have dynamic IP addressing (DHCP, factory setting)
on the network (WLAN) checked on site, and if
required set up, by an IT expert prior to commis-
sioning.
Determine the routing and security parameters in the
IP network (LAN) as follows: Enable Port 80 and
Port 443 for direct outward connections. Have this
checked and, if necessary, set up on site by an IT
expert before commissioning.
Floorstanding boilers
Vitotronic 200, type
KO1B
KO2B
KW1
KW2
KW4
KW5
KW6
KW6A
KW6B
Vitotronic 300, type
KW3
Heat pumps and hybrid
appliances
See www.viessmann.com/vitoconnect
Note
During operation, the Vitoconnect 100 establishes a
secure internet connection to the Viessmann server.
Connecting the Vitoconnect 100 to any other type of
server is not possible.
User account
A valid user account on the Viessmann server is
required for the operation of the Vitoconnect 100,
regardless of which control device is used. Registra-
tion for this occurs automatically during commission-
ing, either via the ViCare app or via the
Vitotrol Plus app (see page 14).
Control device for the ViCare app
Smartphone or tablet PC with the following operating
systems:
Apple iOS, version 8 or higher
or
Google Android, version 4.4 or higher

Preparing for installation

Solid fuel boilers
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Opto1

Table of Contents