Crown EPX-3 Installation & Operation Manual page 14

Electric counter pan steamers
Table of Contents

Advertisement

P
M
REVENTIVE
AINTENANCE
R
S
emoval of
cale
Disconnect the power supply to the appliance before cleaning or servicing.
It is recommended that your steamer be descaled once a week.
Your steamer comes with a sixteen weeks supply of Middleby QuickClean Scale Control product (16 oz. container).
QuickClean is a safe and efficient way to maintain a scale-free environment for your steamer. Weekly descaling will
enhance the life of your steamer. Scale build up can damage your steamer and expose you to costly repairs. Failure or
malfunction of this appliance due to scale build up is not covered under warranty. Read and follow instructions on the
QuickClean bottle.
To order QuickClean or if you have questions about this product call 480-591-4073.
Descaling Procedure
Read and follow instructions on the QuickClean bottle. Use plastic or rubber gloves to avoid skin contact.
If QuickClean comes in contact with skin, rinse with clean water.
1. Set power switch to "OFF".
2. Remove diffuser plate and pan support racks.
3. Fill the cavity with water up to the "WATER LEVEL" line.
4. Spread one scoop of QuickClean (1 oz) evenly to the water.
5. Allow 8 to 16 hours to clean.
6. Drain, rinse and wipe the bottom of the cavity.