ELECTRIC CABINET BASE CONVECTION STEAMER, ECX-16, ECX-24
3.0 INSTALLATION INSTRUCTIONS (Continued)
PLUMBING CONNECTIONS (See Page 4 and 5)
WARNING: Plumbing connections must comply with applicable
sanitary, safety, and plumbing codes.
Water Supply Connection
The incoming cold water supply connection, at the rear of the boiler cabinet, requires 3/8"
tubing and water pressure of 25 - 50 psig. A manual shut-off valve must be provided
convenient to the appliance. This valve should be open when the boiler is in operation.
WARNING: If your equipment was supplied with split water lines
and a water treatment system, connect the system to the connection
marked "FILTERED WATER IN" only (Use cold water). Make a
second connection to the "CONDENSER WATER IN" from a cold and
unfiltered water supply.
FAILURE OR MALFUNCTION OF THIS APPLIANCE DUE TO POOR WATER QUALITY IS
NOT COVERED UNDER WARRANTY. SEE WATER QUALITY STATEMENT (PAGE 4, 5).
Drain Connection
The boiler drain (2" IPS) should be piped to a floor drain near the steamer (NOT directly under
the steamer). There should be no solid drain connection; an "open gap" between the boiler and
the floor drain is required.
MANUAL 10063R4