Page 1
TP-BC12-300 AC to DC12V UNINTERRUPTED POWER SUPPLY User Manual Specifications and Features: 210W Total Max. DC power output 12A Max. (@12V) Charge current 5A Max. (@14V). Net weight, only 4.63 lbs/2.1kg Dimensions 252*54*190 m/m (W*H*D) Over Voltage protection ...
Page 2
PANEL DESCRIPTION Item Name Description Power Switch Control AC power On or Off, Flooded battery Battery Type Selector Gel battery LED Indicators LOAD Load Indicator Light GREEN when the LOAD is working Light YELLOW when the model with AC input and AC Power Indicator power switch is on Light GREEN when BATTERY polarity connection is...
Page 3
INSTALLATION: Before plugging in the model to an AC outlet, please make sure that the proper input voltage is selected on the rear of the unit. Select 115V for 100/110/120 AC operation or 230V for 200/220/240 AC operation. The factory default setting is 230V. Then, connect your device to the LOAD terminal and connect a lead acid battery to the BATTERY terminal, make sure the polarity of battery is correctly connected, select WET for wet battery, GEL for GEL or AGM battery.
Page 4
OPERATION: The PS works as a DC UPS (Uninterruptible Power Supply) or as a backup power supply system. When AC power is applied normally, the model offers a regulated 12V DC output at LOAD terminal for devices and a charging current output on BATTERY terminal for charging a lead acid battery at the same time.
Page 5
When the charger is in charging mode and charge current is more than 2.5A, the CHG indicator light will be YELLOW, when charge current is lower than 1.8A, the charger turns to maintenance mode, the CHG light is off and CHD light is GREEN. All LED indicators will turn off when AC fails except BATT and battery type indicator (WET or GEL).
Page 6
5. The cables for battery connection or device to the PS should be 14AWG min. Please keeping the connect points clean to avoid spark or electrical leakage. 6. When connecting a solar panel or wind turbine controller to the PS, please make sure of the correct polarity.
Page 7
PROTECTION DESCRPTION: Battery Polarity Reverse Protection: when the battery polarity is reversed, the BATT indicator light will display RED and the BATTERY and LOAD terminals will terminate output. Battery reverse will not damage the model if the AC power is off. The AC switch must be turned off at any time when the battery is changed.
Need help?
Do you have a question about the TP-BC12-300 and is the answer not in the manual?
Questions and answers