Sharp PN-V550 Operation Manual page 48

Hide thumbs Also See for PN-V550:
Table of Contents

Advertisement

Controlling the Monitor with a PC (RS-232C)
Others
Function
VOLUME
TEMPERATURE SENSOR
TEMPERATURE ACQUISITION
CAUSE OF LAST STANDBY MODE
Commands for setting of the GAMMA user data
Function
RED GAMMA DATA TRANSFER
GREEN GAMMA DATA TRANSFER
BLUE GAMMA DATA TRANSFER
RED GAMMA DATA READ
GREEN GAMMA DATA READ
BLUE GAMMA DATA READ
USER DATA INITIALIZE
USER DATA SAVE
48
E
Command
Direction
Parameter
VOLM
WR
0-31
DSTA
R
ERRT
R
STCA
W
0
R
Command
Direction
Parameter
UGRW
W
aaxxxx ··· xxxxcc
(xxxx: 32 pieces)
UGGW
W
aa: 01-16
UGBW
W
xxxx: 0000-1023
cc: 00-FF
UGRR
W
1-16 xxxx ··· xxxx
UGGR
W
1-16
UGBR
W
1-16
UGRS
W
UGSV
W
Reply
0-31
0 Internal temperature normal
1 Internal temperature abnormal has occurred and the monitor is in standby mode
2 Internal temperature abnormal occurred (To delete the information of temperature
abnormal, turn off the main power.)
3 Internal temperature abnormal has occurred and backlight brightness is dimmed
4 Temperature sensor abnormal
Value Temperature at temperature sensors 1 through 2 are returned in the following
forms:
[Sensor 1], [Sensor 2]
Indicates a temperature sensor abnormality when "126" is returned.
Initialization
0 No detectable error has occurred
1 Standby mode by POWER button
2 Main power off by the main power switch
3 Standby mode by RS-232C or LAN
4 Input signal waiting mode by No Signal
6 Standby mode by abnormal temperature
8 Standby mode by SCHEDULE setting
20 Standby mode by OFF IF NO OPERATION setting
Reply
aa: Block number
xxxx: 32 pieces of user data
cc: Checksum (ASCII data) of the block number and user data
xxxx: User data of 32 pieces
(xxxx: 32 pieces)
xxxx: 0000-1023
0
Initialize the user data.
0
Save the user data in the monitor.
Control/Response contents
Control/Response contents
*
*

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pn-v551

Table of Contents