NOTE: Maximum Equivalent Vent Length (MEVL) includes standard and concentric vent termination and does NOT include elbows.
Use Table 17 − Deductions from Maximum Equivalent Vent Length to determine allowable vent length for each application.
Unit Size
1 ½
Pipe Dia. (in)
0-2000
20
2001-3000
3001-4000
16
4001-4500
Altitude
4501-5000
15
(feet)
5001-6000
6001-7000
13
7001-8000
10
8001-9000
5
9001-10000
N/A
Unit Size
Pipe Dia.
38
(mm)
0-610
6.0
611-914
0.0
915-1219
4.8
1220-1370
Altitude
1371-1524
(meters)
4.5
1525-1829
1830-2134
3.9
2135-2438
3.0
2439-2743
1.5
2744-3048
NA
NOTES:
1. Inducer Outlet Restrictor disk (P/N 337683-401; 1.25-in. (32 mm) Dia.) available through Replacement Components required for no greater than 5-ft. (1.5
M) TEVL in downflow and horizontal orientations only. Required for installations from 0-2000 ft. (0 to 610 M)above sea level.
2. Inducer Outlet Restrictor disk (P/N 337683-402; 1.50-in. (38 mm) Dia.) available through Replacement Components required for no greater than 5-ft. (1.5
M) TEVL in downflow and horizontal orientations only. Required for installations from 0-2000 ft. (0 to 610 M)above sea level.