WATERPROOF
MABIS
®
Digital Thermometer
.
HEAL
THCARE INC
Thank you for purchasing a MABIS Digital Thermometer. Please read the following
instructions to achieve the most accurate temperatures and safe operation. With
proper care and use, your thermometer will provide you with years of reliable
readings.
What is a "Normal" Temperature?
o
Although the generally accepted "normal" temperature reading is 98.6
F, temperature
o
o
readings can vary from 97
F to 99
F and still may be considered "normal". Variations
in temperature can be attributed to activities such as exercise, smoking, eating and
drinking. Even time of day may influence your temperature. For example, your tem-
perature is lower in the morning than in the afternoon. Other variations may be due
to the location of the temperature reading. While the oral temperature follows the
o
guidelines previously described, a rectal temperature is generally 1.0
F higher.
o
Conversely, an axillary (under the arm) temperature will be 1.0
F lower.
Features of your MABIS Digital Thermometer
BATTERY COVER
DIGITAL DISPLAY WINDOW
PROBE TIP
POWER BUTTON
Cleaning Instructions
Before and after each use, clean the thermometer with a soft cloth and 70%
isopropyl alcohol diluted with water, or wash with COLD soapy water. An intact unit
can be submersed in water or alcohol. However, do not soak for an extended period
of time.
1. The unit must never be sterilized by boiling, gas or steam autoclaves.
2. The use of any other solution or cleaning method beyond the above mentioned
may result in reliability problems with the thermometer and void your warranty.
How to Take Your Temperature
1. Clean and disinfect the thermometer according the instructions provided.
2. Apply a disposable probe cover to the clean, dry thermometer.
3. Determine whether the measurement site will be oral, rectal or underarm.
Note: Measurement time may vary based on the selected site.
4. Press the POWER button (the unit will beep) to activate the thermometer.
This is the LCD display test, which insures all parts of the dis-
play are functioning properly. Continue to hold the button down
and in approximately 2 seconds the display will show the last
recorded temperature as follows.
This display shows the last temperature reading. Within
approximately 2 seconds of releasing the button or if no
reading is stored in memory, the display will read as follows.
This display denotes normal operation.
"Err" denotes a malfunction.
o
The Lo with the flashing
F indicates the thermometer is ready
to take a temperature reading.
Taking an Oral Temperature
1. Using the diagram on the right, place
the probe tip under the tongue as near
as possible to the heat pocket. The dia-
HEAT
POCKET
98.8
o
F
98.8
o
F
gram also shows the temperature vari-
37.1
o
C
37.1
o
C
ables by not placing the tip in the heat
pocket area.
98.4
o
F
98.4
o
F
36.9
o
C
36.9
o
C
Note: Drinking hot or cold fluids, exercis-
ing, smoking or performing other activities
98.1
o
F
36.7
o
C
may raise or lower your temperature.
97.9
o
F
97.9
o
F
36.6
o
C
36.6
o
C
Therefore, it is important to relax for
97.7
o
F
approximately 5 minutes with your mouth
36.4
o
C
closed prior to taking a reading
2. The current temperature is shown and
o
the
F will continue to flash during the reading.
o
3. When the peak temperature has been reached, the
F will stop flashing and the
thermometer will sound four sets of five quick beeps.
4. To turn the unit off, press the POWER button. The unit will automatically shut off
after approximately nine minutes.
Note: The mouth must remain closed during the measurement for the most accu-
rate reading. Opening the mouth could result in an extended measurement time
and may affect the reading.
Taking an Axillary Temperature (under the arm)
1. Wipe the underarm with a dry towel.
2. Place the probe tip under the arm so the tip is touching the skin with the ther-
mometer perpendicular to the body.
3. Position the arm across the chest so the probe tip is well covered by the arm.
This also insures the probe is not affected by the room's air.
4. When the peak temperature has been reached, the
o
F will stop flashing and the
thermometer will sound four sets of five quick beeps.
5. To turn the unit off, press the POWER button. The unit will automatically shut off
after approximately nine minutes.
Note: Axillary temperatures are generally 1.0
o
F lower than oral readings.
Taking a Rectal Temperature
Note: Rectal temperatures are an appropriate and reliable method for infants and
small children. Otherwise, this method should only be used when it is impossible or
impractical to take an oral or axillary temperature.
1. After applying the disposable probe cover, apply a water-soluble lubricant to
the tip.
2. Gently insert the probe a MAXIMUM of 1/2" into the rectum.
o
3. When the peak temperature has been reached, the
F will stop flashing and the
thermometer will sound four sets of five quick beeps.
4. To turn the unit off, press the POWER button. The unit will automatically power
down after approximately nine minutes.
Note: Rectal temperatures are generally 1.0
o
F higher than oral readings.
Using Disposable Probe Covers
It is recommended to use the enclosed disposable probe covers to prevent cross
contamination. Additional probe covers can be purchased from your MABIS Dealer
or with the order form provided.
General Care
1. The thermometer should only be used under the supervision of an adult.
2. Do not walk, run or talk during temperature taking.
3. Clean the thermometer before and after each use.
4. Store the unit in the protective case when not in use.
HEAT
5. Do not bite the probe.
POCKET
6. Do not store the unit where it will be exposed to direct sunlight, dust or humidity.
Avoid extreme temperatures.
7. Dropping or subjecting your thermometer to strong shocks should be avoided.
8. Do not attempt to disassemble the unit, except to replace the battery.
9. If ERR displays and measurement is not attainable, the unit must be replaced.
NOTE: Performance of the device may be degraded if: operated outside of
stated temperature and humidity range; stored outside of stated temperature
and humidity range; thermometer undergoes mechanical shock (drop); patient
temperature is below ambient temperature.
Changing the Battery
The battery in your digital thermometer needs to be
replaced when the "
" symbol appears in the lower
right of the display. Replace the battery with a 1.5V, AG3
alkaline or LR41 silver oxide type or equivalent.
To replace the battery,
1. Slide the battery cap away from the unit.
2. Slide the electrical component that houses the battery
out of the thermometer case approximately a half an
inch.
3. Remove the protective cap from the battery located on
the back side of the thermometer.
4. Using a non-metal pointed tool, carefully remove the battery and insert the new
battery with the negative (–) side facing the back side of the unit.
5. Reattach the battery protection cap.
6. Carefully slide the electrical component back into the thermometer casing.
7. Slide the battery cap back into place, making sure that the cap fits snugly to
protect the battery compartment from moisture.
Note: Please properly dispose the battery away from small children and heat.
Specifications
DISPLAY:
Liquid Crystal Display
DISPLAY RESOLUTION:
4 Digits (1/10TH of a degree increments)
MEASUREMENT RANGE:
90.0
o
F to 111.9
o
F (32.0
ACCURACY:
±0.2
o
F
AVERAGE MEASUREMENT TIME:
Oral 45 seconds. Rectal 30 seconds. Axillary 60 seconds
TONE:
Thermometer beeps when activated and deactivated.
A series of beeps signal when peak temperature is reached.
MEMORY:
Displays last measured temperature
BATTERY:
One, 1.5V, AG3 alkaline
BATTERY LIFE:
Approximately 4,000 measurements
AUTOMATIC SHUT-OFF:
After approximately 9 minutes
o
o
AMBIENT OPERATING TEMPERATURE:
50.0
F to 113.0
F
HUMIDITY:
15% to 95% RH
o
o
STORAGE TEMPERATURE:
-4.0
F to 122.0
F
HUMIDITY:
15% to 95% RH
DIMENSIONS:
4-7/8" x 11/16" x 3/8"
WEIGHT:
0.5 ounces (15.5 grams)
Specifications are subject to change without notice. Meets ASTM Standard E1112.
LIMITED ONE YEAR WARRANTY
This MABIS Digital Thermometer is guaranteed to be free of manufacturing defects for a period of one year from
the date of purchase under normal use. This warranty applies to the original registered purchaser only. All repairs
on your MABIS Digital Thermometer should be sent prepaid to: MABIS Healthcare Inc., Attn: Repair Department,
1931 Norman Drive, Waukegan, IL 60085. MABIS Healthcare shall incur no liability under this warranty for any
damage from any cause other than inherent manufacturing defects. ALL IMPLIED WARRANTES, INCLUDING
MERCHANTABILITY AND FITNESS ARE LIMITED TO THE DURATION OF THIS WARRANTY. THIS WARRAN-
TY DOES NOT INCLUDE ANY LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states do
not allow limitation on how long an implied warranty lasts or do not allow the exclusion or limitation of incidental or
consequential damages, so the above limitations or exclusions may not apply to you. this warranty gives you spe-
cific legal rights and you may also have other rights which vary from state to state.
CUT OUT AND MAIL TO:
MABIS HEALTHCARE INC.
1931 NORMAN DRIVE
WAUKEGAN, IL 60085
THERMOMETER WARRANTY REGISTRATION
(MUST BE COMPLETED WITHIN 10 DAYS OF PURCHASE)
NAME:
ADDRESS:
CITY:
PURCHASED FROM:
CITY:
DATE PURCHASED:
MODEL PURCHASED:
K 15-600-000
USER INFORMATION (OPTIONAL)
K MALE
AGE OF YOUNGEST FAMILY MEMBER
K UNDER 6 MONTHSK 6 MONTHS - 1 YEAR
K 1 - 3 YEARS
PROBE COVER ORDER FORM
CUT OUT AND MAIL TO:
MABIS HEALTHCARE INC.
1931 NORMAN DRIVE
o
C to 43.9
o
C)
WAUKEGAN, IL 60085
Please send
packages of disposable probe covers
#15-618-000 (100 probes per package). Enclosed is $5.00 per
package plus $3.00 for shipping and handling for each order.
PAYMENT METHOD (do not send cash):
Please ship to:
NAME:
ADDRESS:
CITY:
PHONE: (
)
NOTE: This order form is for shipments within the United States and Canada.
STATE:
ZIP:
STATE:
ZIP:
K FEMALE
AGE:
K 3 - 5 YEARS
K OLDER
Check
Money Order
STATE:
ZIP:
#MAB-ACT2020 05/04
©2004 MABIS Healthcare Inc.

Advertisement

loading

Summary of Contents for MABIS 1931

  • Page 1 Note: Rectal temperatures are generally 1.0 F higher than oral readings. This MABIS Digital Thermometer is guaranteed to be free of manufacturing defects for a period of one year from PHONE: ( the date of purchase under normal use. This warranty applies to the original registered purchaser only. All repairs Using Disposable Probe Covers This display denotes normal operation.

This manual is also suitable for:

60085