Compressor
Step
2
Remove the protection
bushing.
3
Disconnect the
compressor lead wires
and the overload
protector.
4
Heat up the brazed part
of the discharge side
pipe and disconnect it.
5
Heat up the brazed part
of the suction side pipe
and disconnect it.
6
Remove the 3 nuts of
the compressor.
7
Lift up the compressor
and remove it.
20
Procedure
W (blue)
U (red)
Protection
bushing
V (yellow)
Overload protector
Brazed part
of discharge
side pipe
(R22758)
Brazed part
of suction
side pipe
Compressor
Nut
(R20869)
Si001554EA
Points
Removal Procedure