Four Way Valve
Step
2
Remove the terminal
cover.
3
Remove the protection
bushing.
4
Disconnect the
compressor lead wires
and the overload
protector.
5
Remove the sheet of
putty.
6
Heat up and disconnect
the every brazed part of
the four way valve.
7
Remove the four way
valve.
18
Procedure
Terminal cover
W (blue)
U (red)
Protection
bushing
V (yellow)
Overload protector
(R20866)
(R22758)
Brazed part
Four way
valve
Putty
(R20868)
Si001554EA
Points
Removal Procedure

Hide quick links: