Amplitude suppression coefficient
05.14
0~12
The Lower limit frequency of oscillation suppression
05.15
0.0~【05.16】
The upper limit frequency of oscillation suppression
05.16
【05.15】~【00.05】
In case of motor oscillation, it is necessary to set the effective value of 05.00 thousand bits, turn on the oscillation suppression function, and then adjust it by
setting the oscillation suppression coefficient. In general, the oscillation amplitude is large, so it is unnecessary to set the oscillation suppression coefficient of 05.13,
05.14 ~ 05.16; In case of special occasions, they should be used together from 05.13~05.16.
Selection of wave-by-wave current limit
05.17
000~111
LED bit:In acceleration
0:invalid
1:valid
LED ten bits:In deceleration
0:invalid
1:valid
LED hundred-bits: In constant speed
0:invalid
1:valid
LED Thousand bits:Reserved
Output phase lost protection detection coefficient
05.18
0.00~20.00
When the ratio of the maximum value to the minimum value in the three-phase output current is greater than this coefficient and the duration exceeds 6 seconds,
the frequency inverter reports the output current imbalance fault EPLI;; Output open-phase protection is invalid when 05.18=0.00.
Frequency drop coefficient of instantaneous power failure
05.19
0:the instantaneous stop function is invalid
1~9999
Instantaneous power down loss frequency reduction voltage point
05.20
220V:180~330V
380V:300~550V
If the inverter bus voltage drops below 05.20* rated bus voltage, and the instantaneous stop control is valid, the instantaneous stop starts to act.

06 group: communication parameters

Local Address
06.00
0~247
250V