• [D000512] Emergency driver unlocking should be performed
according to the Installation and OperatingInstructions
of the driver manufacturer.
• [D000667] Do not operate the drive unit if it requires ser-
vicing or adjustment. Improper installation or balance
of the door may cause severe injury.
Wicket door
• [C000088] Wicket door may only be opened manually by pushing
the handle in the direction of door opening. Wicket door should
be opened and closed smoothly, without sharp jerks that negatively
influence its durability, operation and safe usage.
• Wicket door is mounted and adjusted properly, if the leaf moves
smoothly, and its operation is easy.
• Avoid strong striking the door leaf against frame, so called „door bang-
ing" that may result in paint coating damage and glazing cracking,
in door leaf deformation and negatively influence operation of hard-
ware, hinges, gaskets.
• It is prohibited to overload the wicket door leaf, leave the objects with-
in the door leaf movement area as well as operate the door by force.
• [C000089] It is recommended to equip the wicket door with closer,
which should only be used for self-closing of the wicket door after
its previous manual opening.
• [C000090] Each time before operating the door, it is necessary
to make sure that the wicket door is closed. The wicket door in-
stalled in a door with an electric drive unit should be fitted with a limit
switch that prevents the drive from starting when the wicket door
is opened and stops the door when the wicket door opens while the
drive unit operates.
• [C000091] It is prohibited to apply extra force (other than the clos-
er) to fully close or speed up the wicket door closing that may result
in the closer damage or maladjustment.
• [C000209] It is prohibited to put any objects between the opening
or closing door leaf and frame.

12. ROUTINE MAINTENANCE INSTRUCTIONS

12.1. ACTIVITIES WHICH MAY BE PERFORMED BY THE OWNER
AFTER CAREFUL READING THE INSTRUCTION
[D000166] Before any maintenance or inspection of a ga-
rage door, disconnect the drive from power source. Also
a battery power supply should be disconnected if it has
been delivered.
[C000476] Do the following at least every 3 months:
[C000470] Clean the external/internal door leaf surface with a sponge
and clean water or varnish cleaning products available in stores. Do not
use cleaning products that could scratch the surface, sharp tools, nitro
solvent-based products and detergents. Do not use power washers.
[B000217] Cleaning panes in the glazing (small windows, glazed al-
uminium profiles).
Before cleaning, if unsure as to the material the glazing is made of,
make sure the pane is scratch-resistant. Low-hardness materials have
low resistance to mechanical damage and scratch easily (e.g. stand-
ard SAN, PMMA).
Follow the recommendations below to minimize the risk of scratching
and other pane surface damage:
• first, clean the pane surface with compressed air or flush it with run-
ning water to remove dirt and dust particles that could scratch the
pane surface
• next, use the appropriate soft cleaning tool. Non-abrasive cleaning
agents can be used. A neutral pH, alcohol-free, delicate wash-
ing-up liquid is an appropriate cleaning agent. It is recommended
to test the cleaning agent on a small surface of the pane.
• use a soft water-absorbing chamois leather or cotton cloth to dry
the pane surface
• the temperature of the pane surface and water should not exceed
25°C when cleaning
Do not use the following:
• rubber squeegees, scrapers and blades
• abrasive agents, solvents and alcohol-based window cleaners
• power washers
• excessive amount of water which may lead to pane fogging
[D000231] Clean the stainless steel decoration elements, e.g. with Wurth
IOiK/BS/UniPro/04/2020/ID-98589
Operating and Maintenance Manual – Sectional garage door UniPro
Technical description
cleaning agent for stainless steel, at least two times per month (avoid
contact of the clearing agent with the door leaf).
[B000220] Carry out ongoing inspections of the product at least
every 6 months and perform the following (if applicable):
• check hinge connections, running rollers, and springs, if required
grease with e.g. HWS-100 Würth semi-solid grease,
• check the elements fastening the product to the wall, bolts (screws),
and feed rollers, make sure to eliminate any irregularities found, do not
operate the product until the irregularities are eliminated,
• make sure electrical cables show no signs of wear,
• clean the photocell covers or the signal lamp cover lens on a reg-
ular basis,
• replace the transmitter batteries at least every 12 months,
• check whether the operator is properly fixed,
• do not lubricate the lock cylinder with oil, apply graphite grease
if required,
• check the operation of the emergency opening mechanism supplied
with the drive unit,
• perform control device maintenance in accordance with the control
device Operating Manual.
[B000221] Doors with an electric drive unit require the following ac-
tions to be performed at least every 6 months (if applicable):
• check whether limit switches are properly adjusted (operate the door
and observe the location where the door stops); when the door stops
in the closed position, the cables should remain under tension; when
the door stops in the open position, the bottom seal should not be lo-
cated above the clear opening,
• check whether the electrical protective devices operate properly
by simulating the operating conditions,
• check the photocells by simulating the operating conditions - when
the light beam is interrupted, the door should stop and reverse,
• check the lock or latch closing sensor - when the lock or latch
is closed, the door should not operate,
• check the light curtain - when the light beam is interrupted, the door
should stop and reverse,
• check the wicket door closing sensor - when the wicket door is open
the door should not operate,
[C000453] Check whether the overload switch (applies
to operators with the overload adjustment feature) and
the optical strip operate properly. The door should stop
and reverse when the door leaf touches an object (made
of hard expanded polypropylene, XPS or wood) 80 [mm]
in diameter and 50 [mm] high, placed on the floor.
ANTI-DROP SAFETY DEVICE
O
Maintenance
Anti-drop safety device does not require special maintenance. Howev-
er, it is necessary to keep it clean and protect against dust, especially
sand. In case of any cables damages, it should be immediately replaced.
• [B000007] It is prohibited to keep using the door, if any
faults in its operation, or damage of its components are
found. Do not operate; contact an authorised service cen-
tre or a Professional Installer.
• [D000668] Failure to comply may result in severe injuries
due to crushing by the door or other hazards.
• [A000114] The Manufacturer shall not be liable for any
damage caused by failure to comply with safety rules,
the Installation and Operating Instructions or applicable
legal requirements.
Service inspection
12.2. ACTIVITIES TO BE PERFORMED BY A PROFESSIONAL
INSTALLER ONLY
[D000166] Before any maintenance or inspection of a ga-
rage door, disconnect the drive from power source. Also
a battery power supply should be disconnected if it has
been delivered.
[A000093] Periodically inspect the door at least every 12 months.
• [C000474] identify the door: door type, serial number
• check door signage, warning and information labels, replace if missing
• check the Warranty Sheet or the Door Report Book - validity, cur-
rent entries
EN