Operating Instruction; Opening And Closing - Wisniowski UNIPRO Operating And Maintenance Manual

Sectional garage door
Table of Contents

Advertisement

Available languages

Available languages

EN
• when finishing / refurbishing the room, the product should be pro-
tected from plaster, paint and solvent splashing,
• Avoid exposure of the product to: lime, cement, alkalis and cleaning
agents (e.g. brighteners or abrasive pastes).
• Limit the wet finishing work to minimum. If the mortar stains the prod-
uct surface, remove the material immediately.
• [B000231] provide free water drainage in the bottom seal area,
• if when lifting the door leaf/curtain you experience excessive resist-
ance, check the technical condition of door hinges, rollers, cables, and
springs; if irregularities are found, perform all the necessary adjust-
ments (or replace as needed) in accordance with the door Installation
and Operating Manual,
• do not activate the "automatic closing" function or the "self-hold
when closing" function if the door is not fitted with photocells or the
safety edge,
• if the cable break safety device or the spring break safety device
is triggered, replace any damaged elements,
• if the door features a wicket door, do not lift the door leaf/curtain if the
wicket door is not locked up,
• do not change the phase sequence of the three-phase voltage after in-
stalling and commissioning the door, as this may lead to door damage,
• [B000189] It is prohibited to remove any structural com-
ponents! This may result in damage to parts which normally
ensure the safe use of the product. Alteration of any com-
ponents or parts is prohibited.
• [B000210] Do not modify the adjustments done by the
Professional Installer.
• [A000062] Do not perform any product repairs
on your own.
• [C000260] Do not install any additional infills or thermal
insulation on the door leaf/curtain without a written con-
sent from the Manufacturer. The door drive unit is precisely
matched with the door leaf/curtain weight and any addition-
al elements can cause overload or malfunction.
• [C000092] Call a Professional Installer to check and adjust
the position of limit switches after completing the finish-
ing or refurbishment works related to the modification
of the floor level and after the disassembly or reassem-
bly of the garage door or the operator.
• [D000315] the activity is not performed within the guar-
antee services.
• [C000461] During the full operating cycle of the door, the
user shall visually monitor the door operating area and
keep all bystanders away until the door is fully opened/
closed.
• [B000202] [!]In case of electrically driven doors, where
a lock or a locking bolt is applied, installing a lock sen-
sor or a locking bolt sensor is recommended. Otherwise,
if an actuator is connected to the power network the lock-
ing bolt or the lock should be blocked in an open position.

11. OPERATING INSTRUCTION

• [C000383] Do not stay, pass, run or drive under the door
when it is in motion. Before opening or closing, ensure
that no persons, and especially children or any objects,
are in the path of the moving garage door. No persons, ob-
jects or vehicles are allowed to stay within the clearance
of the open door.
• [C000076] WARNING: Do not obstruct the door leaf move-
ment area. Make sure that no persons, especially children,
or objects stand in the way of a closing or opening door leaf.
• [C000077] No barriers may stand in the way of a door leaf.
• [C000079] The door may be approached only when its mo-
tion (opening or closing) is finished. Approaching the door
in motion is not allowed.
• [D000143] Do not obstruct the door or the drive motion
area. Do not put fingers or objects into the slide rail.
• [C000384] Do not use the garage door to lift any objects
or people.
• [A000103] Do not use faulty products! Do not use the prod-
uct and contact an authorized service centre if the product
is malfunctioning or its subassemblies are damaged.
• [A000125] Do not remove, alter or disable any protec-
tive equipment.
• [B000194] The product can only be operated when all the
4
Operating and Maintenance Manual – Sectional garage door UniPro
Technical description
required safety devices are in place and if these devices
are operational.
• [B000211] Keep batteries, rechargeable batteries or other
small power sources out of the reach of children. Hazard
of swallowing by children or pets!
Deadly hazard!
If this emergency occurs, immediately consult a medical
doctor or seek medical attention. Do not shorten the battery
leads. Do not throw the batteries into fire. Do not recharge
non-rechargeable batteries. Explosion hazard!
• [C000080] Remote control transmitters or other con-
trol equipment to activate the door should be kept out
of reach of children, to avoid unauthorised activation.
Do not allow children to play with control devices. Trans-
mitters should be kept in dry places.
• [C000335] Damage caused by wind load. Do not oper-
ate the door when the wind load exceeds the wind load
resistance class provided on the door nameplate. Wind
pressure causes the door leaf/curtain to deflect. In the
case of strong wind load, the door curtain and structure
can be damaged.
• [B000103] IMPORTANT! Damage due to temperature dif-
ference. The temperature difference between the outdoors
(environment) and indoors (room) can cause product ele-
ments to bend (bimetal effect). If this occurs, operating the
product can lead to damage.
• [C000042] This equipment can only be operated by chil-
dren above 8 years of age, persons with impaired physical/
and or mental performance and inexperienced users un-
der supervision or according to the operating manual and
with the principles of safe use and related hazards prop-
erly explained. Do not allow children to clean or perform
maintenance works on the device. Mind that children must
never play with this equipment.
• [D000668] Failure to comply may result in severe injuries
due to crushing by the door or other hazards.
11.1.

OPENING AND CLOSING

[B000093] Doors with electric drive unit must be opened according
to Assembly and Operating Instruction of the drive.
Opening - the door should be operated manually, using the relevant
outside or inside handles/ pulls. Improper operation of the door may
cause accident.
Closing - the door should be closed manually by pushing it vigorous-
ly using the handle. As a result, the door self-locking bolts will latch
on proper door frame elements.
Door bolting (lock) - doors can be fitted with locks that can be locked
by turning the key anticlockwise by 360 degrees when the door is not
power operated.
Door unbolting (lock) - use the key or blocking bolt:
• from outside - turn the key 360° clockwise,
• from inside - press the interlock lever on the side of the lock. The le-
ver will rest in the low position. Push the lever up to close the door.
• [A000133] The latch or lock should be opened and closed
smoothly, without any jerking which decreases the dura-
bility and safety of use.
• [B000104] All the manually operated products should
be opened and closed smoothly, without any jerking
which decreases product durability and safety of use.
• [C000334] Each time the door is about to be started, make
sure that the lock or door bolt is not in the closed posi-
tion. Starting the door is allowed only when the lock and/
or door bolt are in the open position, or the door is fitted
with an automatic locking set.
• [C000078] The door can be opened and closed using
the drive unit only when the door is within the opera-
tor's sight, unless it is fitted with suitable safety devices.
• [B000154] In the door operated with an electric drive, in nor-
mal operating conditions, the drive unit is coupled with the
door at all times. The drive can be uncoupled only in emer-
gencies, e.g. in the case of drive breakdown. After the drive
unit was uncoupled, following the manual opening and
closing of the door, the drive should be re-coupled. The
un-coupling may not be performed while the drive unit
is in use as this may cause permanent damage to the
drive unit.
IOiK/BS/UniPro/04/2020/ID-98589

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents