nanoe Discharge Abnormality
o
Abnormal detection condition
After 30 minutes nanoe power ON, abnormal signal is being detected continuously for 5s.
Action after abnormal detection condition fulfilled
Abnormal discharge counter +1, nanoe power OFF for 30 minutes and then restart. When abnormal
discharge counter ≥ 12, abnormal code: H67 in analyze area (Area where abnormal code not
displayed) will be memorized.
Abnormal discharge counters clear condition
Discharge counter will be cleared when operation become normal for 50 mins above or when
operations stop.
11.12 ECONAVI Operation
Area of human availability, activity level and absent is judged based on pulses by using 2 infrared sensors. The
internal setting temperature shift, fan speed and horizontal airflow direction are adjusted in order to provide
comfort environment while maintain the energy saving level.
ECONAVI start condition:
When ECONAVI button is pressed.
o
ECONAVI stop conditions:
When ECONAVI button is pressed again.
o
When unit is OFF by OFF/ON button.
o
When unit is OFF when OFF TIMER activates.
o
When unit is OFF by AUTO OFF/ON button at indoor unit.
o
When QUIET operation activates.
o
When
button is pressed.
o
When POWERFUL operation is selected.
o