Download Print this page

Digicom SNM15 Operation Manual page 77

Advertisement

SNM15
REG.
RANGE UNIT
NUM.
S0
0-255 RING
S1
0-255 RING
S2
0-127 ASCII
S3
0-127 ASCII
S4
0-127 ASCII
S5
0-127 ASCII
S6
2-255 SECONDS 02 Waiting time for dial tone
S7
1-255 SECONDS 30 Waiting time for carrier
S8
0-255 SECONDS 02 Pause time for ","
S9
1-255 1/10 s.
S10
1-255 1/10 s.
S12
20-255 1/50 s.
S13-17
S25
0-255 SECONDS 05 DTR delay
S26
0-255 0.02 s.
S29-31-32-33
S48
0-127 ASCII
S49
0-127 ASCII
S50
0-127 ASCII
6.24
DECIM. DESCRIPTION
DEF.
00 Rings awaited for connection
00 Detected rings counter
43 Escape character
13 Return
10 Line feed
08 Backspace
06 Answer tone detection time 06 (F)
07 Disconnect time for lack
of carrier
50 Watch time for Escape
BIT MAPPED REGISTERS
00 RTS/CTS delay
BIT MAPPED REGISTERS
13 Fallback character
17 XON character
19 XOFF character
V.25 bis
V.25bis
(Default)
I
I
I
CR (F)
LF (F)
BS (F)
I
I
I
07 (F)
I
5 (F)
0 (F)
P
P
P
Digicom SpA

Advertisement

loading