3-in-1 photoelectric smoke + fire + carbon monoxide smart alarm
Table of Contents

Advertisement

This is a 3-in-1 combination smoke + fire + carbon monoxide (CO) alarm. The 10 year sealed
battery provides continuous protection even in the event of a power outage .
• There are three basic smoke alarm types: Universal Smoke Sensing Technology
and Photoelectric .
• Universal Smoke Sensing Technology
Alarm Technology . Alarms containing Universal Smoke Sensing Technology are effective at
detecting fast flaming fires faster than the maximum allowable alarm limit, and are effective
at detecting slow smoldering fires.
• Ionization smoke alarms are typically more effective at detecting fast flaming fires—fires
which consume combustible materials rapidly and spread quickly. Sources of these fires may
include paper burning in a wastebasket, or kitchen grease fires.
• Photoelectric smoke alarms, on the other hand, are typically more effective at detecting slow
smoldering fires—fires which burn for hours before bursting into flame. Sources of these
fires may include cigarettes burning in couches or bedding.
• Installing alarms containing Universal Smoke Sensing Technology ensures maximum detec-
tion of both types of fires from a single alarm, while eliminating the need for a combination of
ionization and photoelectric smoke alarms .
Smart Alarm Technology virtually eliminates nuisance alarms caused by non-hazardous
sources such as every day cooking smoke and steam
Permanent Power battery provides continuous protection and eliminates low battery chirps .
Never replace batteries .
Lithium Free 10 Year Sealed Power Supply features Duracell
Technology alkaline batteries providing a safer, greener alternative
• IMPORTANT: ALARMS WILL NOT WORK WITHOUT POWER. Therefore, installing an
alarm with a sealed battery or an alarm powered from two different power sources can give
an extra measure of protection . A hardwired alarm with backup battery power will provide
protection in the event of an AC power failure . Battery operated alarms cannot work if the
batteries are missing, disconnected or dead . If you are concerned about the limitations of the
battery or AC power, install both types of alarms .
• PROPERLY LOCATE THE ALARM TO AVOID NUISANCE ALARMS. Using an ionization
smoke alarm without Universal Smoke Sensing Technology in a smokey area, such as a
kitchen, or in a high humidity area near a shower, can cause nuisance/false alarms . Also,
humid areas near a shower can cause nuisance/false alarms .
• DO NOT DEACTIVATE THE BATTERY TO QUIET A NUISANCE/FALSE ALARM. The
alarm will not provide protection if it is not receiving power . Properly locate the alarm to
avoid nuisance/false alarms .
• SMOKE, CO OR GAS ALARMS MAY NOT ALWAYS WARN ABOUT DANGERS CAUSED
BY CARELESSNESS. Safety hazards such as smoking in bed, violent explosions, escap-
ing gas, improper storage of flammable materials, overloaded electrical circuits, children
playing with matches, natural causes such as lightning and arson . Prevention and appliance
maintenance is the best safeguard .
• INSTALLING ALARMS MAY MAKE YOU ELIGIBLE FOR LOWER INSURANCE RATES,
BUT ALARMS ARE NOT A SUBSTITUTE FOR INSURANCE. Home-owners and renters
alike should continue to insure their lives and properties .
• SMOKE ALARMS CANNOT DETECT FIRES IF THE SMOKE DOES NOT REACH THEM.
Smoke from fires may not reach the sensing chamber and set off the alarm. Do not obstruct
airflow around the smoke alarm or place in areas of obstructed airflow.
• SMOKE ALARMS MAY NOT BE EFFECTIVE IN VARIOUS AREAS. For example: (1) Fires
where the victim is intimate with fire due to a person's clothes catching fire while cooking; (2)
Fires where the smoke is prevented from reaching the alarm due to a closed door or other
obstruction; (3) Incendiary fires where the fire grows so rapidly that an occupant's egress is
blocked even with properly located alarms .
ALARM TECHNOLOGY & FEATURES
®
The enclosed alarm is a 3-in-1 Photoelectric
Smoke + Fire + Carbon Monoxide Smart Alarm.
KEY PRODUCT FEATURES

ALARM LIMITATIONS AND FUNCTIONS

is an ionization alarm containing patented Smart
Page 2
Duralock Power Preserve™
®
, Ionization
®

Advertisement

Table of Contents
loading

Table of Contents