TOUR GRADE SERIES
CONFIG/SERVICE/Last Log: Shows point in time and type of the
last entry in the event history. If service is needed, the code shown
here provides relevant detail of what might have caused the
malfunction for your Electro-Voice Service partner.
CONFIG/SERVICE/Module Signature: In the event of failure or
malfunction, the information shown here provides relevant detail of
what might have caused the malfunction for your Electro-Voice
Service partner.
CONFIG/SERVICE/Firmware Version: This menu item shows
version and date of the firmware that is actually installed in the
power amplifier.
Structure of the MODULE CONFIG menu
The MODULE CONFIG menu provides access to RCM-26 remote control module settings, which are
available from the LC display of the power amplifier. This menu cannot be accessed during operation of
the power amplifier. Accessing this menu is only possible when the power amp is switched off.
The following steps open the MODULE CONFIG menu:
1. If the power amplifier is powered on or in standby mode, use the mains switch on the front panel to
switch the power amp off.
2. Simultaneously press the
and ENTER buttons and keep them pressed.
3. Use the power switch on the front panel to switch the power amplifier on.
The power amp enters standby mode and the MODULE CONFIG
menu appears on the display.