Download Print this page

Electro-Voice TG5 Specifications page 2

Tour grade series
Hide thumbs Also See for TG5:

Advertisement

RCM-26 DSP Module
• 2-in-2 Speaker Controller with IIR and Linear
Phase FIR Filters
• 96 kHz Sample Rate,116 dB Dynamic Range
• 24 Bit Linear AD/DA, AES/EBU In/Out
• 2 GPIO's, RS232 Interface, CAN-Bus
• 300 MIPS Processing Power for Real Time
DSP Editing and Zero-Latency FIR Filers
Specifications
Max. Midband Output Power THD=1 KHz, 1 kHz, Dual Channel
Max.Rated Output Power THD , 0,1%, 20 Hz - 20 kHz
Max.Single Channel Output Power Dynamic Headroom, IHF-A
Max.Bridged Ouput Power THD = 1%, 1 kHz
Maximum Voltage Swing
THD1%, 1 kHz
Power Bandwidth
THD = 1%, ref. 1 kHz, 1/2 power @4
Voltage Gain ref. 1 kHz
Input Sensitivity (rated power @8 )
THD at rated output power
IMD-SMPTE (60 Hz, 7 kHz)
DIM30 (3,15 kHz, 15 kHz)
Max. Input Level
Crosstalk (1 kHz, rated output power)
Frequency Response (ref. 1 kHz)
Input Impedance
Damping Factor (1 kHz)
Slew Rate
S/N Ratio (A-weighted, 32 dB gain)
Output Noise, A-weighted
Output Stage Topology
Power Requirements
Power Consumption
1/8 max. output @ 4
Protection
Cooling
Ambient Temperature Limits
Dimensions (W x H x D)
Net Weight
Americas–Headquarter Americas
Europe, Africa & Middle-East
Telex Communications Inc.
Headquarter EAME
12000 Portland Ave South,
EVI Audio GmbH
Burnsville, MN 55337, USA
Hirschberger Ring 45, D-94315,
USA–
Ph: 1-800-392-3497
Straubing, Germany
Fax: 1-800-955-6831
Phone: +49 9421 706-0,
Canada–
Ph: 1-866-505-5551
Fax: +49 9421 706-265
Fax: 1-866-336-8467
Latin America–
Ph: 1-952-887-5532
France: EVI Audio France S.A.,
Fax: 1-952-736-4212
Parc de Courcerin,
Allée Lech Walesa,
F 77185 Lognes, France
Phone: +33 1-6480-0090
Fax: +33 1-6006-5103
• Unique System Supervision and Diagnostiocs
• Total Control Through IRIS-Net Software
• Compatible with all IRIS-Net Capable Devices:
TG-5
2
1900 W
4
1450 W
8
850 W
2
--
4
1200 W
8
600 W
2
4
8
2
4
8
39 / 33 / 32 dB (switchable)
0 / +6 / +7 dBu (switchable)
+22 dBu (9.75Vrms)
10 Hz - 30 kHz (± 1 dB)
30 V/Ìs
109 dB
Class-H Grounded Bridge
100 - 240V, 50/60 Hz or 100V, 50/60 Hz
1000 W
Audio Limiters, High Temperature, DC, HF, Short Circuit, Back-EMF,
Peak Current Limietrs, Inrush Current Limiters, Turn-On Delay,
Mains Circuit Breaker Protection, Mains Overvoltage Protection
Front-to-rear, 5-stage fans
+5°C - +40°C (40°F - 105°F)
483 x 88.1 x 512 mm (19" x 3.46" x 20.15")
14.2 kg (31.4 lbs)
UK: Shuttlesound,
4 The Willows Centre,
Willow Lane, Mitcham,
Surrey CR4 4NX, UK
Phone: +44 208 646 7114
Fax: +44 208 254 5666
Asia & Pacific Rim–Headquarter Asia
Singapore: Telex Pte. Ltd.
3015A Ubi Road 1,
05-10 Kampong Ubi Industrial Estate,
Singapore 408705
Phone: +65 6746-8760,
Fax: +65 6746-1206
(Load Monitoring and Additional impedance
Measurements - System Check)
RCM24
(DSP controlled Precision Series Amplfiers)
NetMax
®
N8000
10 Hz - 50 kHz
41 / 35 / 32 dB (switchable)
0 / +6 / +9 dBu (switchable)
<0.05%
<0.05%
< 0.02%
< -80 dB
20 k
> 400
< -70 dBu
Japan: EVI Audio Japan Ltd.
5-3-8 Funabashi, Setagaya-Ku,
Tokyo, Japan 156-0055
Phone: +81 3-5316-5020,
Fax: +81 3-5316-5031
Hong Kong: Telex EVI Audio (HK) Ltd.
Unit 5,1/F, Topsail Plaza
11 On Shum Street
Shek Mun,Shatin HK
Phone: +852 2351-3628,
Fax: +852 2351-3329
TG-7
3500 W
2500 W
1500 W
--
2100 W
1050 W
4500 W
3200 W
1800 W
-
7000 W
5000 W
125V
35 V/Ìs
111 dB
1450 W
14.5 (32 lbs)
China: Telex EVI Audio (Shanghai) Ltd.
Room 2210-2215,
Tower B, Far East International Plaza,
No. 317, Xianxia Road,
Shanghai, China, PC: 200051
Phone: +86 21-6235-1677
Fax: +86 21-6235-1676

Advertisement