A.O. Smith DSE-5 Instruction Manual page 19

Commercial electric water h
Table of Contents

Advertisement

state
The water heater is not in an active heating cycle. This usually indicates the temperature in the tank has reached the
Standby
Operating Set Point and the control system has terminated the heating cycle.
Heating
The control system is in the Heating Mode. At least one heating element has been energized.
The control system has detected/declared an Alert Condition. The controls system will continue heating operation.
Alert
However, a Qualified Service Agent should be contacted to check/service the water heater.
The control system has detected/declared a Fault Condition. The control system will discontinue heating operation and
Fault
"lock out." Power to the water heater must be cycled off and on to reset the control system. Note; cycling power will not
reset the control system until the condition that caused the fault has been corrected.
Menus
Most commonly accessed menu. Operating Set Point, Differential settings, Tank Temperature and Tank Probe
Temperatures
Offset are located in this menu.
Current Operating State/Mode (heating/standby etc) and status (open/closed - on/off - yes/no) of monitored
Heater Status
water heater functions and components are displayed in this menu.
Seven day 24 hour time clock with temperature set back capability to reduce operating costs during unoccupied
Economy Mode Setup
or reduced demand periods.
The control system's CCB (Central Control Board - see wiring diagrams) features on board SPDT (single pole
double throw) relay contacts for building EMS (Energy Management System) notification of operational conditions
Alarm Output Setup
such as Fault Conditions and heating mode status. This menu features a list of user definable conditions for
relay activation.
Temperature units (°F or °C), appearance (brightness contrast) and backlight delay user adjustable settings are
Display Settings
located in this menu.
Elapsed time of operation, total heating cycle time, heating cycle count, heating element(s) cycle count and on
Heater Information
time along with UIM and CCB software revisions can be viewed in this menu.
Current Fault/Alert
Displays any current Alert or Fault messages.
Retains 9 event history of Fault/Alert messages with time stamp. The Fault History is useful when dealing with
Fault History
intermittent operational problems or when the customer has reset the control system prior to a service agent's
arrival.
Total accumulated number each individual Fault condition has occurred is displayed in this menu. This
Fault Occurrence
running total of Fault Occurrences can be useful in determining which (if any) operational problems have been
persistent.
This control system feature allows the user to restore control system user settings to their factory default settings.
Restore Factory Defaults
Alarm Output Setup and Display Settings menu items ARE NOT changed when factory defaults are restored.
Accessible by pressing the corresponding Operational Button from most menus and screen displays. This menu
provides access to instructions and explanations for user settings, Operating States, Status Icons, manufacturer's
Help Menu
web address, technical support phone number and service agent contact information.
taBle 4 - operatInG states
descrIptIon
taBle 5 - control systeM Menus
descrIptIon
19