Propane Conversion Kit Installation Instructions (Continued)
16. If the combustion is satisfactory and the exhaust analysis is within the range,
complete the conversion by attaching the conversion plate and label
(Figure 8).
17. IMPORTANT: Using a permanent fine-tip marker, mark on the conversion
label the date of conversion and the name and address of the party making
the conversion. Attach the conversion label on the area reserved for it on
the existing appliance label. Using an alcohol swab, clean the surface
before attaching the label. Peel off the backing strip and apply the label
with uniform pressure over the entire surface. See Figure 9.
Figure 8.
Figure 9.