Before installing Cabletron Systems 7F06-02 Module, review the network
requirements outlined in this chapter. All requirements included in this
chapter should be met to ensure satisfactory performance of the 7F06-02
Module. Failure to do so may result in unsatisfactory network
performance.
2.1
FPIM MODULE SPECIFICATIONS
This module uses Fiber Port Interface Modules (FPIM) to provide front
panel cable connections. The FPIMs are user-installable. Refer to Section
3.2, Installing FPIMs.
2.1.1
FPIM-00 and FPIM-01
The FPIM-00 and FPIM-01 provide a multimode fiber connection. The
FPIM-00 uses a MIC style connector and the FPIM-01 uses an SC type
connector. The specifications for both devices are listed in Table 2-1,
while the transmitter power parameters are provided in Table 2-2.
Table 2-1 FPIM-00 and FPIM-01 Specifications
Parameter
Receive
Sensitivity
Peak Input
Power
7F06-02 FDDI SmartSwitch Interface Module User's Guide
CHAPTER 2
NETWORK REQUIREMENTS
Typical Value
-30.5 dBm
-7.6 dBm
Worst
Case
-28.0 dBm
—
-8.2 dBm
—
Worst
Typical
Case
Budget
Budget
—
—
2-1