Check Operation - Electrolux ICON Professional E30DF74GPS Installation Instructions Manual

30" & 36" dual fuel range
Hide thumbs Also See for ICON Professional E30DF74GPS:
Table of Contents

Advertisement

30" & 36" DUAL FUEL RANGE INSTALLATION INSTRUCTIONS

9.2 Check Operation

Refer to the Use and Care Guide and the Electronic Oven
Control Guide packaged with the range for operating
instructions and for care and cleaning of your range.
Remove all packaging from the oven before testing.
1. Burner Bases and Burner Caps
This range is equipped with sealed burners as shown
(Figure 17). All pieces are at their place. Take note
where they are. Remove all packaging material
located under the Dual Surface burner head. Make
sure the burner is properly aligned and leveled. NOTE:
There are no burner adjustments necessary on this
range.
30" Range
Burner Cap
Burner Base
36" Range
Fixed Burner Ring
Dual Surface
Burner
Figure 17
2. Turn on Electrical Power and Open Main Shutoff
Gas Valve
3. Check the Igniters
Operation of electric igniters should be checked after
range and supply line connectors have been carefully
checked for leaks and range has been connected to
electric power. To check for proper lighting:
a.Push in and turn a surface burner knob to the LITE
position. All electronic surface ignitors will spark at the
same time. However, only the burner you are turning
on will ignite.
b.The surface burner should light once the flow of gas
reached the surface burner. Each burner should light
within four (4) seconds in normal operation after air
has been purged from supply lines. Visually check that
burner has lit.
c. Once the burner lights, the control knob should be
rotated out of the LITE position.
There are separate ignition devices for each burner. Try each
knob separately until all burner valves have been checked.
(Model with Electric Oven and Gas Cooktop)
Burner Cap
Fixed Burner Ring
and Burner Base
Regular Burner
4. Adjust the "LOW" Setting of Regular Burner (see
figure 17) on the Surface Burner Valves (Figure 18):
a. Push in and turn control to LITE until burner ignites.
b. Quickly turn knob to LOWEST POSITION.
c. If burner goes out, reset control to OFF.
d. Remove the surface burner control knob and
decorative ring.
e. Insert a thin-bladed screwdriver into the hollow valve
stem and engage the slotted screw inside. Flame size
can be increased or decreased by turning the screw.
Turn counterclockwise to increase flame size. Turn
clockwise to decrease flame size. Adjust flame until
you can quickly turn knob from LITE to LOWEST
POSITION without extinguishing the flame. Flame
should be as small as possible without going out.
Note: Air mixture adjustment is not required on surface
burners.
10
Figure 18

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Icon professional e36df76gps

Table of Contents