Installation Procedures - Haier AB072XCEAA Operation & Installation Manual

Cassette type air conditioner
Table of Contents

Advertisement

Installation Procedures

1.Selection of Installation Place
(1) Place above the ceiling where it is enough space to arrange the unit.
(2) Place where the drainage pipe can be arranged well.
(3) Place where inlet and outlet air of indoor and outdoor unit will not be blocked.
(4) Do not expose the unit to the place with heavy oil or moisture (e.g.kitchen and workshop).
(5) Do not set the unit in the place where destructive gas (such as sulfuric acid gas) or pungent
gas (thinner and gasoline) concentrates and retains.
(6) Place strong enough to support the unit .
(7) No expensive articles such as television and piano below indoor unit.
(8) Enough space for maintenance.
(9) Place more than 1m away from television and radio to avoid disturbing television and radio.
(10) Easy for maintenance.
2.Installation Preparation
(1) Position of ceiling opening between unit and suspending bolt (front view of unit).
Distance between
suspending bolts 535mm
Indoor unit 570mm
Ceiling opening 650mm
Ornament panel 700mm
(2) Prepare all piping (refrigerant,water drainage )and wires (connection wire of remote controller,
indoor unit connection wires) to the indoor unit before installation in order to connect indoor unit
immediately after installation.
Air outlet
Air inlet
Air outlet
1.5m
2.5m Over
Overlap between ceiling and
ornament panel shall be 25mm
Ceiling
13
1.5m
Ornament panel
: http://splitoff.ru/tehn-doc.html
Suspending bolts

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ab092xceaaAb122xceaaAb142xceaa

Table of Contents