Download Print this page

Aktakom ASE-2105 User Manual page 3

Temperature controlled desoldering station

Advertisement

2. Technical Specification
STATION
INPUT
VOLTAGE
POWER
CONSUMPION
MAIN FUSE
VACUUM
PRESSURE
3. Operating Instruction
3.1 Place the desoldering gun in the holder separately. Then
connect the plug to the station and turn clockwise to tighten
the plug nut. Check that the power switch is on the "OFF"
position. Connect the control unit to the power supply and
switch on the power. Then a self-test is carried out . The system
will switch on automatically to show the set temperature and
displays the value.
3.2 The display and temperature setting
The digital display:
① shows the actual temperature of the desoldering tip .
②shows the setting temperature: Pressing the "UP" or
"DOWN" button can switch the digital display to the set point
3
110-240VAC
90W
3.15A
600mm Hg
www.tmatlantic.com
DESOLDER GUN
VOLTAGE
POWER
TEMPERTURE
HEATING
ELEMENT
24V
90W
HEAT UP RATING
200W
160°C-480°C
PTC CERAMIC
HEATER

Advertisement