Clr Errors; Figure 7-5. Clear Errors Screen - ADTRAN ESU LT User Manual

Hide thumbs Also See for ESU LT:
Table of Contents

Advertisement

CLR ERRORS

61200410L1-1B
QRSS ACT TS0s
The ESU LT has an internal QRSS pattern generator and
detector. The pattern only appears in the TS0s assigned to the
Nx56K/64K port. The QRSS test pattern can be used in
conjunction with network loopbacks to perform end-to-end
tests.
511 Active TS0s
The 511 pattern is generated and checked by the Nx56K/64K
serial interface. It only appears in the TS0s assigned to the
Nx56K/64K port.
When used in conjunction with the payload loopback at the
far end, an end-to-end integrity check can be made on the
DTE ports.
All Zeros
Generates an all zero's pattern in every channel.
All Ones
Generates an all one's pattern in every channel.
has two functions.
C
E
LR
RRORS
1.
To clear out the 511 error total when you press
2.
To display a total of the 511 errors. If 511 errors are being
received, the display is updated accordingly. See Figure
7-5.
ESU LT User Manual
Chapter 7. Test Menu

Figure 7-5. Clear Errors Screen

.
Enter