into instant heating mode in 10seconds. If user needs to change temperature setting
under instant heating mode, simply press down set button and enter into temperature
change process. Change the temperature as mentioned.
3.2.2 Set parameters of night heating mode
Press down the mode button and change from instant heating mode to night heating
mode. Screen shows temperature setting for last time by blinking. Preliminary default
temperature setting is 70 C. Blinking reminds user whether it is necessary to change
heating temperature on this mode. If it is required, user can change the temperature
as per instant heating mode. Temperature regulating range is 40-75 C. After user finishes
temperature change, press down set button, or carry on no action within 10seconds,
for confirming setting. If it is not necessary to change heating temperature, user does
not act and system enters into night heating mode in 10seconds. If user needs to change
temperature setting at the night heating mode, simply press down set button and enter
into temperature change process. Change the temperature as mentioned.
3.2.3 Economic heating mode
If user selects economic heating mode, it is not required to set any parameter. System
heats water to 60 C in the manner of instant heating and maintain the temperature.
3.2.4 Intelligent timing heating mode
Press down mode button and change from economic heating mode to intelligent timing
heating mode. Screen shows time setting for last time by blinking. (Preliminary default
value is 7:00.) Meanwhile timing indication "1" blinks, giving user hint to set first
waterapplication time. Press down +/- button once for short term and water-application
time increases/ reduces 0.5hour.Press down set button for confirmation when user
finishes setting first water-application time. And system memorizes the setting thereafter
enters into successive parameter, i.e. setting first application temperature. Screen shows
application temperature for last time by blinking. (Preliminary default value is 70 C. )
Set application temperature as per immediate heating mode. Press down set button for
confirmation when user finishes setting. And system memorizes the setting thereafter
enters into successive parameter, i.e. setting second water-application time. Screen
shows time setting for last time by blinking. (Preliminary default value is 21:00.) Meanwhile
timing indication "2" blinks. Set time as mentioned. Press down set button for confirmation
when user finishes setting second water-application time. And system memorizes the
setting thereafter enters into successive parameter, i.e. setting second application
temperature. (Preliminary default value is 70 C.) Screen shows same as mentioned.
And set temperature as before.
Press down set button for confirmation when user finishes setting second application
temperature. And system selects intelligent keep warm. Screen shows selection for last
time by blinking. (Default status is open.) Press down "+" button to open intelligent
keep
warm. Press down "-" button to close intelligent keep warm. After
setting, press down
set button and system memorizes setting.
Then setting process exits.
Note: a. For any setting, if user does not act within 10seconds, system still maintains
prior setting. Setting process exists. System enters into intelligent timing mode.
b. There are two timing, user can cancel any one. Press down +/- button at the same
time for 3seconds when to set certain water-application time. Then user can cancel
corresponding timing. And it is not required to set relevant application temperature. Or
user can set the same time for two water applications to cancel one timing.