When wiring, proceed as follows:
Ensure the poles are connected correctly and that the
plugs are connected properly without gaps
Observe the minimum bending radius of 24.5 mm of
the solar cables that are used.
5.3
Connection of the solar modules
Please observe the information provided by the manufacturer
of the inverter when connecting the solar modules to an in-
verter.
5.4
Grounding of the solar modules
To minimise the risk of an electrical shock, the frames of the
solar modules should be grounded.
Assembly material
stainless steel screw, diameter 6 mm with serrated
washer and nut
suitable grounding cable
NOTE
Ensure that the anodised layer of the frame is penetrated and a
secure electrical contact is created with the frame.
Procedure
 Please see the drawing in Appendix 1 of these in-
structions for the positions of the grounding holes.
 Screw the grounding cable firmly to one of the ground-
ing holes using the stainless steel screw and a min.
torque of 8 Nm.
6

Maintenance

Only specially trained and qualified person-
nel may service the solar system.
KYOCERA solar modules are designed for long-term service
and are almost maintenance-free.
6.1
Safety information relevant for maintenance
Warning!
Risk of falling when working on roofs.
Use suitable fall protection equipment.
Observe the accident prevention regulations.
6.2
Cleaning the solar module
When the slope is adequate (> 15 degrees), the solar mod-
ules do not need to be cleaned thanks to the self-cleaning
effect of the rain. If heavily soiled, clean with plenty of water,
a mild detergent and a soft cloth/sponge.
6.3
Solar module maintenance
The system should be inspected once a year with regard to
the following:
Secure hold and no rust on any of the attachments
Secure connection, cleanliness and that all cable con-
nections are free of corrosion
Soundness of cables and front glass
KYOCERA Assembly and Maintenance Instructions, August 2012
7

Disclaimer

KYOCERA's "Limited Warranty for Photovoltaic-Modules"
does not apply if this assembly and maintenance instruction
is not strictly observed. KYOCERA will not assume any liabil-
ity for damage arising from improper use, wrong assembly,
operation or maintenance.
8

Customer service / Contact

KYOCERA Fineceramics GmbH
Solar Division
Fritz-Mueller-Strasse 27
D-73730 Esslingen / Germany
 for technical questions:
Tel: +49 (0)711-93934-998
Fax: +49 (0)711-93934-861
E-Mail: pv-support@kyocera.de
 for general questions:
Tel: +49 (0)711-93934-999
Fax: +49 (0)711-93934-950
E-Mail: solar@kyocera.de
You will find more information and the latest data sheets,
warranty conditions, certificates etc. in the download
section of our website: www.kyocerasolar.eu
Please contact us if you need more information that is
not provided in our website.
Appendix 1
(+)
(-)
 Grounding holes
 Junction box
 Assembly holes
 Module frame
 Solar cable