Pressure test
The Rapid injector is used as a pressure test
point.
1. Connect the pressure gauge to the Rapid
injector.
2. Examine the supply pressure by turning the
Rapid burner and one other burner fully on,
and lighting them. The pressure must be:
a) 20 mbar for Natural Gas
b) 29 mbar for LPG, butane only
c) 37 mbar for LPG, propane only.
3. Turn the taps off and disconnect the
pressure gauge.
4. Make sure that all burners work correctly.
Checking the hob burners
1. Lift the lid.
2. Put on the burner crowns and caps. Make
sure that they are correctly seated.
3. Put on the pan supports.
4. Light one of the hob burners.
To light the hob burner refer to the "Ignition
of the hob burners".
Check if the flame is regular.
Check each of the burners.
5. Turn the knob for the hob to the off position.
Checking the oven burners and the grill
1. Put in the deep pan and the trivet.
2. Light the oven burner.

Energy efficiency

Product information for hob according to EU 66/2014
Model identification
Type of hob
Number of gas burners
Energy efficiency per gas burner
(EE gas burner)
Energy efficiency for the gas hob (EE gas hob)
24
To light the oven burner refer to the "Ignition
of the oven burners".
Check if the flame is regular.
Check each of the burners.
3. Turn the knob to the off position.
Checking the Lid Safety Device
1. Lift the lid.
2. Light one of the hob burners.
To light the hob burner refer to the "Ignition
of the hob burners".
3. Close the lid. There should be no gas
supply to the hob burners. The burner goes
out.
4. Turn the knob to the off position and lift the
lid. The gas supply should be restored to
the hob burners, when you turn the knob on.
Electrical installation
This appliance is supplied with a main plug and
a main cable.
ZCG43210BA
ZCG43210WA
ZCG43210XA
Hob inside Freestanding Cooker
4
Left Front - Rapid
Left rear - Semi Rapid
Right front - Auxiliary
Right rear- Semi Rapid
WARNING!
The manufacturer is not responsible
if you do not follow the safety
precautions from Safety chapters.
The spark generator is active all the
time if the phases are not connected
correctly.
www.zanussi.com