Safety Information . . . . . . . . . . . . . 2
and Performance Claims . . . . . . . . 3
About the Softener . . . . . . . . . . . . 4
Before you Start . . . . . . . . . . . . . . . 7
Installation Instructions . . . . . . . . . 11
Care and Cleaning . . . . . . . . . . . . 25
Routine Maintenance . . . . . . . . . . 27
Warranty (U.S.) . . . . . . . . . . . . . . . 38
Warranty (Canada) . . . . . . . . . . . 39
Consumer Support . . . . . . . . . . . . 42
If you have any questions or concerns when installing or maintaining
your water softener, call our toll free number at 800-952-5039 (US)
or 866-777-7627 (Canada), or visit geappliances.com. When you call,
please be prepared to provide the model and serial number of your
product. This information can be found on the rating decal located on
the rim under the salt cover.
GE is a trademark of the General Electric Company. Manufactured under trademark license.
Systems tested and certified by NSF International
against NSF/ANSI Standard 44 for the chemical
reduction claims specified on page 3, and certified
to NSF/ANSI 372.
Systems Tested and Certified by the Water Quality
Association against CSA B483.1.
7375781
49-6000221 Rev. 0 04-19 GEA
OWNER'S MANUAL
AND INSTALLATION
INSTRUCTIONS
Model GXSHC40N
Write the model and
serial numbers here:
Model # _____________
Serial # _____________
To find these numbers,
lift the cover and look
on the rim below the
control panel.

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for GE GXSHC40N

  • Page 1: Table Of Contents

    This information can be found on the rating decal located on the rim under the salt cover. GE is a trademark of the General Electric Company. Manufactured under trademark license. 7375781 49-6000221 Rev. 0 04-19 GEA...
  • Page 2: Safety Information

    IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING SAFETY PRECAUTIONS For your safety, the information in this manual must be followed to WARNING minimize the risk of electric shock, property damage or personal injury. WARNING WARNING A copper or Do not use with galvanized cold water pipe may be used to water that is microbiologically unsafe or of ground electrical outlets in the home.
  • Page 3: Specifications And Performance Claims

    Operational efficiency is the actual efficiency after the system has been installed. It is typically less than the efficiency, due to individual application factors including water hardness, water usage, and other contaminants that reduce the softener’s capacity. Specifications Model GXSHC40N Rated Capacity* (Grains@ Salt Dose) 11,700 @ 2.3 lbs 31,500 @ 8.7 lbs. 40,000 @ 15.1 lbs.
  • Page 4: About The Softener

    About the water softener system SERVICE When the water softening system is providing After a period of time, the resin beads become soft water, it is called “Service.” During service, coated with hard minerals and they have to hard water flows from the house main water be cleaned.
  • Page 5 About the water softener system NORMAL OPERATION, CONTROL DISPLAYS During normal operation, the present time of The system will automatically recharge at the day and AM or PM and DAYS TO EMPTY preset recharge time as needed. show in the control display area. FEATURE: OPTIONAL RECHARGE CONTROLS Sometimes, a manually started recharge may RECHARGE TONIGHT...
  • Page 6 In these conditions, faucet because it has oxidized before reaching you may wish to consider purchasing a GE the home. It appears as small cloudy yellow, point-of-entry household filtration system with a orange, or reddish suspended particles.
  • Page 7: Before You Start

    Before you start BEFORE YOU START The water softener requires a minimum water flow of 3 gallons per minute at the inlet. Maximum allowable inlet water pressure is 125 psi. If daytime pressure is over 80 psi, nighttime pressure may exceed the maximum. Use a pressure reducing valve if necessary (Adding a pressure reducing valve may reduce the flow).
  • Page 8: Installation Requirements

    Installation Requirements LOCATION REQUIREMENTS Consider all of the following when selecting an DO NOT RUN HOT WATER THROUGH THE installation location for the water softener. SOFTENER. Temperature of water passing Do not locate the water softener where freezing through the softener must be less than 120° F. temperatures occur.
  • Page 9 Installation Requirements PLUMBING CODES VALVE DRAIN REQUIREMENTS All plumbing must be completed in accordance Using the flexible drain hose (included) (See with national, state and local plumbing codes. Figure 2), measure and cut to the length In the state of Massachusetts: The needed.
  • Page 10 Installation Requirements INLET/OUTLET PLUMBING 3-VALVE BYPASS SYSTEM For soft water service: Open the inlet and REQUIREMENTS outlet valves and close the bypass valve. Always install either a single bypass valve For bypass hard water: Close the inlet and (provided),as shown in Figure 4, or, if desired, outlet valves and open the bypass valve.
  • Page 11: Installation Instructions

    Installation Instructions TYPICAL INSTALLATION Ground Wire 1” NPTM Clamp (not included) Pipe (not included) Threaded Conditioned Hard Water Adaptor (not Water to Outside included) Faucets Main Water Pipe Plug into Incoming 1” NPTF controller Hard Water Sweat Adaptor Cover Motorized Water Plug-in (not Shutoff valve...
  • Page 12 Installation Instructions TURN OFF WATER SUPPLY 1. Close the main water supply valve, located near the well pump or water meter. Salt Cover Nozzle Venturi 2. Open all faucets to drain all water from Assembly house pipes. NOTE: Be sure not to drain water from the Brinewell Nut - Ferrule water heater, as damage to the water heater...
  • Page 13 Installation Instructions GETTING ACCESS TO MAIN CONTROL BOARD (TO PLUG IN WATER SHUTOFF VALVE) 1. Pull out both tabs on back of the top cover to unlock cover. INSTALL MOTORIZED WATER Top Cover SHUTOFF VALVE Install the included water shutoff valve on the threaded installation adapter leading to the water softener’s INLET.
  • Page 14 Installation Instructions MOTORIZED WATER SHUTOFF VALVE 6. With power off, plug the shutoff valve’s To manually operate the motorized water cable into this connector. shutoff valve, pull out the round knob on the valve and turn it until the red line in the sight glass matches the desired (open or closed) position.
  • Page 15 Installation Instructions COMPLETE INLET AND OUTLET • If making a soldered copper installation, do all PLUMBING sweat soldering before connecting pipes to the NPT adapters and bypass valve. Torch WARNING heat will damage plastic parts. A copper or WARNING galvanized cold water pipe may be used to ground electrical outlets in the home.
  • Page 16 Installation Instructions INSTALL VALVE DRAIN HOSE TEST FOR LEAKS To prevent air pressure in the water softener 1. Measure and connect the 3/8”drain line and plumbing system, complete the following (provided) to the water softener valve drain steps in order: fitting.
  • Page 17 Installation Instructions ADD WATER AND SALT TO THE SALT SANITIZE THE WATER SOFTENER / STORAGE TANK SANITIZE AFTER SERVICE 1. Open salt hole cover, remove the brinewell WARNING cover and pour about 3 oz. (6 tablespoons) of household bleach into the softener EXCESSIVE WEIGHT HAZARD: brinewell.
  • Page 18: Programming The Softener

    Programming the Water Softener When the transformer is plugged into the SET TIME OF DAY electrical outlet, a model code and test number 1. Press MODE/SET button until the arrow (example: y4.1 & H40) are shown in the points to CLOCK. display.
  • Page 19 Programming the Water Softener SET WATER HARDNESS NUMBER SET RECHARGE (STARTING) TIME 1. Press the MODE/SET button until the arrow 1. Press the MODE/SET button until the arrow points to HARDNESS. A flashing 25 will points to RECHARGE. appear in the display. Salt Level Salt Level Clock...
  • Page 20 Programming the Water Softener SET SALT LEVEL DAYS TO EMPTY 1. Press the MODE/SET button until the arrow The words DAYS TO EMPTY and a number points to SALT LEVEL. are shown in the lower half of the display. This information is shown in the normal run display.
  • Page 21 Appliance Communication: WiFi Connect (For customers in the United States, its Territories, and Canada) If your Water Softener is GE Appliances WiFi • WiFi communication requires WiFi Connect capable, a WiFi communication connectivity and electrical power at the card is built into the product allowing it to location of the softener.
  • Page 22 Programming the Water Softener OPTIONAL CONTROL SETTINGS The controller display has several options and PRERINSE features. If your water contains LOW SALT ALARM sediment, the prerinse feature will remove The LOW SALT ALARM, sediment from the resin when enabled, will sound bed prior to regeneration.
  • Page 23 Programming the Water Softener FEATURE: OTHER DATA DISPLAY RESETTING TO FACTORY DEFAULT These models have an option to have the To reset the electronic controller to its factory run display indicate different information. The default for all settings (time, hardness, etc.): information displayed on the top half of the 1.
  • Page 24 Programming the Water Softener POWER OUTAGE MEMORY ERROR SIGNALS If electrical power to the water softener is If there is an error code lost, “memory’’ built into the timer circuitry will detected, the blue keep all settings for up to 6 hours. While the indicator light will flash Call for Service power is out, the display is blank and the water...
  • Page 25: Care And Cleaning

    Care and cleaning ADJUSTING YOUR WATER HARDNESS The blend adjusting knob (Figure 16) gives the NOTE: To meet the water softener performance ability to finely adjust hardness of the treated specifications and reduction of barium and water leaving the water softener. If slightly harder radium claims the adjustable hardness must be water is desired than is normally delivered by the kept in the “OFF”...
  • Page 26 Always add if less GE Appliances recommends using Super Iron than 1/4 full. Be sure the brinewell cover is on. to clean your resin bed if your iron content ®...
  • Page 27: Routine Maintenance

    Routine Maintenance CLEANING THE NOZZLE AND VENTURI bridge with the tool. Do not pound on the walls ASSEMBLY of the tank. To help dissolve the salt bridge pour one gallon of warm water (not hot) into the tank. A clean nozzle and venturi is needed for the If the wrong kind of salt made the bridge, take it water softening system to work properly.
  • Page 28: Before You Call For Service

    • Hardness setting too low. Check hardness setting and adjust. Verify hardness of supply water—from local water company, water test or call the GE Appliances Answer Center (800-952-5039 in US). • Salt Bridge—salt solidifies above water level so that brine water is not in contact with salt. See the Breaking a Salt Bridge section.
  • Page 29 Before you call for service Problem Possible Cause What to do Water hard Using hot water while the • Avoid using hot water during water softening sometimes water softening system is system recharge because the water heater will regenerating refill with hard water. See Automatic Hard Water Bypass During Recharge section.
  • Page 30 Before you call for service Problem Possible Cause What to do Excessive/high Valve drain hose pinched, • A restriction in this drain hose may prevent level of water in plugged, elevated too high or proper operation of the nozzle and venturi and brine tank otherwise restricted reduce or prevent brine draw during recharge.
  • Page 31 Before you call for service Problem Possible Cause What to do Error Codes 1,3,4,5 Wiring may have worked • Unplug external power supply. on Control loose in the control • Remove control cover, release clips on side. • Check for loose/incorrect wiring connections to electronic board or switch.
  • Page 32 3. Symbols in the display indicate POSITION 6. Press and hold the MODE/SET button until switch operation, (see Figure 19). the mode code (H40 for GXSHC40N) shows in the display (see Figure 20). This code Switch is open Switch is closed identifies the softener mode.
  • Page 33 Advanced troubleshooting for service Service: Manually Advance Recharge Check NOTE: The control display must show a steady 4. Press the RECHARGE button to move the time (not flashing). water softening system into fast rinse. Again look for a fast drain flow. Allow the water 1.
  • Page 34: Exploded View/Parts List

    Exploded View...
  • Page 35 Exploded View 136/140 Wear Strip Seal Cross-section View...
  • Page 36 Parts List Reference GE Appliances Part Description Quantity Part. No GXSHC40N 0002 WS31X10051 BACK COVER, ELECTRONICS 0003 WS35X10001 O-RING SEAL KIT 0004 WS35X21986 DECAL, FACEPLATE 0005 WS07X10004 HOSE, DRAIN, 20 FT. 0006 WS31X10044 FILTER SCREEN 0007 WS14X10002 DISTRIBUTOR, TOP 0008...
  • Page 37 Parts List Reference GE Appliances Part Description Quantity Part. No GXSHC40N 0110 WS03X10011 SEAL, O-RING, 1.125 X 1.37 0111 WS19X10005 SUPPORT, SCREEN 0112 WS03X10013 SCREEN 0113 WS22X10036 FLOW PLUG, .15 GPM 0114 WS08X10008 GASKET, NOZZLENENTURI 0115 WS03X10073 CONE SCREEN 0116 WS22X10021 PLUG, FILL FLOW, .30 GPM...
  • Page 38: Warranty (U.s.)

    This limited warranty is extended to the original purchaser for products purchased for home use within the USA. If the product is located in an area where service by a GE Appliances Authorized Servicer is not available, you may be responsible for a trip charge or you may be required to bring the product to an Authorized GE Appliances Service location for service.
  • Page 39: Warranty (Canada)

    From the date of the materials or workmanship. During this limited one-year warranty, original purchase GE Appliances will also provide, free of charge, all labor and related service to replace the defective part. Three Years The electronic monitor, if it fails due to a defect in materials or From the date of the workmanship.
  • Page 40 All sales in Iowa require the following signature before consummation of sale. These signatures must be retained by seller/renter for 2 years minimum. Buyer/Renter ______________________________________________ Date _______________ Seller ____________________________________________________ Date _______________ Seller’s Address ________________________________________________________________ Seller’s Phone No. ______________________________________________________________ Model GXSHC40N...
  • Page 41 Notes...
  • Page 42: Consumer Support

    Have a question or need assistance with your appliance? Try the GE Appliances Website 24 hours a day, any day of the year! You can also shop for more great GE Appliances products and take advantage of all our on-line support services designed for your convenience.
  • Page 43 Esta información se puede encontrar en la calcomanía de calificación ubicada en el borde debajo de la tapa de la sal. GE es una marca registrada de General Electric Company. Fabricado bajo licencia de marca.
  • Page 44: Información Sobre Seguridad

    INFORMACIÓN IMPORTANTE DE SEGURIDAD. LEA TODAS LAS INSTRUCCIONES ANTES DEL USO PRECAUCIONES DE SEGURIDAD Por su seguridad, se debe seguir la información en este manual ADVERTENCIA con el fin de reducir el riesgo de una descarga eléctrica, daños a la propiedad o daños personales. ADVERTENCIA ADVERTENCIA Una tubería de...
  • Page 45 Especificaciones Modelo GXSHC40N Capacidad Evaluada* (Granos por Dosis de Sal) 11,700 @ 2.3 lbs 31,500 @ 8.7 lbs.
  • Page 46: Especificaciones Y Dimensiones 45 Acerca Del Suavizante

    Sobre el sistema de descalcificación de agua SERVICIO Cuando el sistema descalcificador de agua está Después de un período de tiempo, la capa de resina proporcionando agua descalcificada, a esto se le se obstruye o se satura con los minerales duros y llama “Servicio”.
  • Page 47 Sobre el sistema de descalcificación de agua FUNCIONAMIENTO NORMAL, PANTALLAS DE CONTROL Durante el funcionamiento normal, la hora actual del El sistema se recargará de forma automática en el día y AM o PM y DAYS TO EMPTY (DÍAS HASTA tiempo de recarga presente, según sea necesario.
  • Page 48 Agua Dura). condiciones, es recomendable considerar la compra Los hierros férricos (agua roja), y asociados de un sistema de filtración para hogar GE Point-Of- con bacterias y organismos son insolubles. Este Entry con un filtro para la reducción de cloro.
  • Page 49: Antes De Comenzar

    Antes de comenzar ANTES DE COMENZAR El suavizante de agua requiere un flujo mínimo de agua de 3 galones por minuto en la entrada. La presión de entrada de agua máxima tolerable es de 125 psi. Si la presión del día supera los 80 psi, es posible que la presión nocturna supere el máximo.
  • Page 50: Requisitos De Instalación

    Requisitos de Instalación REQUISITOS DE UBICACIÓN con la luz solar, temperaturas extremas de calor o frío, u otras formas de abuso. Considere todo lo siguiente al seleccionar una NO HAGA CORRER AGUA CALIENTE A ubicación de instalación del suavizante de agua. TRAVÉS DEL SUAVIZANTE La temperatura del No coloque el suavizante de agua donde haya agua que pasa a través del suavizante deberá...
  • Page 51 Requisitos de Instalación CÓDIGOS DE PLOMERÍA REQUISITOS DEL DRENAJE CON VÁLVULA Toda la plomería deberá ser completada de acuerdo con los códigos de plomería nacional, estatal y local. Para el uso de una manguera de drenaje flexible (incluida) (vea la Figura 2), mida y corte hasta En el estado de Massachusetts: En el Commonwealth la extensión necesaria.
  • Page 52 Requisitos de Instalación REQUISITOS DE PLOMERÍA INTERIOR/ 3-SISTEMA DE DESVIACIÓN CON EXTERIOR VÁLVULA Siempre instale una válvula de desviación simple Para el servicio con agua suave: Abra las válvulas (provista), como se muestra en la Figura 4, o, si lo internas y externas y cierre la válvula de desviación.
  • Page 53: Instrucciones De Instalación

    Instrucciones de Instalación INSTALACIÓN TÍPICA Cable a Tierra (no Adaptador Abrazadera (no incluido) Roscado Pipa incluida) NPTM de 1” Agua Acondi- Agua Dura (no incluido) cionada hacia Grifos Externos Tubería de Agua Enchufe en el Principal Agua Dura Adaptador de controlador Entrante Transpiración...
  • Page 54 Instrucciones de Instalación CIERRE EL SUMINISTRO DE AGUA IMPORTANTE: No coloque cuñas directamente debajo del tanque de almacenamiento de sal para nivelar el 1. Cierre la válvula del suministro principal de agua, suavizante. El peso del tanque, cuando esté lleno de ubicada cerca de la bomba del pozo o del medidor agua y sal, podrá...
  • Page 55 Instrucciones de Instalación OBTENCIÓN DE ACCESO AL TABLERO DE CONTROL PRINCIPAL (PARA ENCHUFAR LA VÁLVULA DE CIERRE DE AGUA) 1. Empuje hacia fuera ambas lengüetas en INSTALACIÓN DE LA VÁLVULA DE la parte trasera de la tapa superior para CIERRE DE AGUA CON MOTOR desbloquear la tapa.
  • Page 56 Instrucciones de Instalación VÁLVULA DE DESCARGA DE AGUA 6. Con la alimentación apagada, enchufe el MOTORIZADA cable de la válvula de cierre en este conector. Para operar manualmente la válvula de cierre de agua motorizada, saque la perilla redonda de la válvula y gírela hasta que la línea roja en la mirilla coincida con la posición deseada (abierta o cerrada).
  • Page 57 Instrucciones de Instalación COMPLETE LA PLOMERÍA DE ADVERTENCIA ENTRADA Y SALIDA Si se harán ADVERTENCIA soldaduras para la conexión de las tuberías, use Una tubería de sólo soldadoras y fundidores libres de plomo cobre o galvanizada de agua fría podría usarse para para evitar el envenenamiento con plomo.
  • Page 58 Instrucciones de Instalación INSTALE LA MANGUERA DE DRENAJE PRUEBA DE PÉRDIDAS DE LA VÁLVULA Para evitar la presión de aire en el suavizante de agua y en el sistema de plomería, complete los 1. Mida y conecte la línea de drenaje de 3/8” siguientes pasos en orden: (provista) al accesorio de drenaje de la válvula 1.
  • Page 59 Instrucciones de Instalación AGREGUE AGUA Y SAL AL TANQUE DESINFECTE EL SUAVIZANTE DE DE ALMACENAMIENTO DE SAL AGUA/ DESINFECTE LUEGO DEL SERVICIO ADVERTENCIA 1. Abra la tapa del agujero de sal, retire la tapa del RIESGO DE pozo de salmuera y vierta alrededor de 3 oz. (6 PESO EXCESIVO: Cuente con la ayuda de dos o cucharones) de blanqueador de hogar en el pozo más personas para mover e instalar las bolsas de...
  • Page 60: Programación Del Suavizante

    Programación del Suavizante de Agua CONFIGURE LA HORA DEL DÍA Cuando el transformador está enchufado en el tomacorriente eléctrico, un código de modelo 1. Presione el botón MODE/SET (Modo/ y número de evaluación (ejemplo: y4.1 & H40) Configuración) hasta que la flecha apunte a aparecen en la pantalla.
  • Page 61 Programación del Suavizante de Agua CONFIGURE EL NÚMERO DE DUREZA CONFIGURACIÓN DEL TIEMPO (INICIAL) DE RECARGA DEL AGUA 1. Presione el botón MODE/SET (Modo/ 1. Presione el botón MODE/SET (Modo/ Configuración) hasta que la flecha apunte a Configuración) hasta que la flecha apunte a RECHARGE (Recargar).
  • Page 62 Programación del Suavizante de Agua CONFIGURE EL NIVEL DE SAL DÍAS HASTA VACIARSE 1. Presione el botón MODE/SET (Modo/ Las palabras DAYS TO EMPTY (DÍAS HASTA Configuración) hasta que la flecha apunte a VACIARSE) y un número se muestran en la mitad SALT LEVEL (Nivel de Sal).
  • Page 63 Si su Suavizante de Agua cuenta con la función y corriente eléctrica en la ubicación del suavizante. WiFi Connect de GE Appliances, el producto contará La conectividad de la aplicación no funcionará en con una tarjeta de comunicación WiFi incorporada caso de que cualquiera de ambas falle.
  • Page 64 Programación del Suavizante de Agua CONFIGURACIONES OPCIONALES DEL CONTROL La pantalla del controlador cuenta con varias PRE ENJUAGUE opciones y funciones. Si el agua contiene ALARMA DE SAL BAJA sedimentos, la función de pre enjuague eliminará Una vez activada LOW SALT los sedimentos del fondo ALARM (Alarma de Sal Baja), de resina antes de la...
  • Page 65 Programación del Suavizante de Agua FUNCIÓN: PANTALLA DE OTROS que se regrese a la pantalla del tiempo actual. DATOS REAJUSTE A FALTA DE FÁBRICA Estos modelos tienen una opción para que Para reiniciar el controlador electrónico de todas la pantalla indique información diferente. La las configuraciones al ajuste de fábrica por omisión información mostrada en la mitad superior de (hora, dureza, etc.)
  • Page 66 Programación del Suavizante de Agua MEMORIA POR CORTE DE CORRIENTE SEÑALES DE ERROR Si se corta la corriente del suavizante de agua, Si se detecta un código la “memoria” incorporada en los circuitos del de error, la luz azul temporizador mantendrán todas las configuraciones indicadora titilará...
  • Page 67: Cuidado Y Limpieza

    Cuidado y limpieza AJUSTE DE LA DUREZA DEL AGUA de ajuste de la dureza se deberá mantener en la posición “OFF” (Cerrada”). La posición cerrada se La perilla de ajuste de mezcla (Figura 16) le da la logra cuando la perilla de ajuste de mezcla se rota posibilidad de ajustar finamente la dureza del agua completamente en dirección de las agujas del reloj tratada, dejando el suavizante de agua.
  • Page 68 Siempre agregue sal GE Appliances recomienda el uso de Super Iron cuando la cantidad sea inferior a ¼. Asegúrese de para limpiar el lecho de resina si el contenido ®...
  • Page 69: Rutina De Mantenimiento

    Rutina de Mantenimiento LIMPIEZA DEL ENSAMBLE DE LA Si el puente se formó con el tipo de sal inadecuado, retírelo. Luego llene el tanque con sal en pepitas o BOQUILLA Y EL VENTURI bolitas únicamente. En áreas húmedas, es mejor Una limpieza de la boquilla y el venturi es necesaria llenar el tanque con menos sal, con mayor frecuencia para que el sistema suavizante funcione de forma...
  • Page 70: Antes De Solicitar El Servicio Técnico

    • Configuración de dureza demasiado baja. Controle la configuración de la dureza y haga un ajuste. Verifique la dureza del agua suministrada - de la empresa de agua local, evaluación del agua o llame a GE Appliances Answer Center (800-952-5039 en EE.UU.).
  • Page 71 Antes de solicitar el servicio técnico Problema Causa Posible Qué hacer Agua dura a veces Uso de agua caliente mientras el • Evite usar agua caliente durante la recarga del sistema suavizante de agua se está sistema suavizante de agua, ya que el calentador regenerando de agua se volverá...
  • Page 72 Antes de solicitar el servicio técnico Problema Causa Posible Qué hacer Nivel excesivo/alto La válvula de la manguera de drenaje • Cualquier restricción en la manguera de drenaje de agua en el tanque está pinzada, atascada, demasiado podrá impedir un funcionamiento correcto de la de salmuera elevada o de algún modo restringida boquilla y el venturi y reducir o impedir el ingreso de...
  • Page 73 Antes de solicitar el servicio técnico Problema Causa Posible Qué hacer Códigos de Es posible que el • Desenchufe el suministro de corriente externo. Error 1, 3, cableado se haya • Retire la tapa del control, libere los sujetadores al costado. 4, 5 en el aflojado en el •...
  • Page 74 6. Mantenga presionado el botón MODE/SET funcionamiento del interruptor de POSICIÓN. Vea (Modo/ Configuración) hasta que el código la Figura 19 del modo (H40 para GXSHC40N) aparezca en El interruptor esta abierto El interruptor esta cerrado la pantalla. Este código identifica el modo del suavizante.
  • Page 75 Solución de problemas avanzados para el servicio técnico Servicio: Control de Recarga Avanzado en forma Manual NOTA: La pantalla de control debe mostrar el horario 4. Presione el botón RECHARGE (Recarga) para de manera fija (no titilando). pasar el sistema suavizante de agua al enjuague rápido.
  • Page 76: Vista Ampliada/ Listado De Piezas

    Vista Expandida...
  • Page 77 Vista Expandida 136/140 Wear Strip Seal Cross-section View...
  • Page 78 Vista Expandida Nº de Nº de Pieza de Descripción de la Pieza Cantidad Referencia GE Appliances GXSHC40N 0002 WS31X10051 TAPA TRASERA, CIRCUITO ELECTRÓNICO 0003 WS35X10001 KIT DE SELLADO DEL ANILLO O 0004 WS35X21986 CALCOMANÍA, PLACA FRONTAL 0005 WS07X10004 MANGUERA, DRENAJE, 20 PIES...
  • Page 79 Vista Expandida Nº de Nº de Pieza de Descripción de la Pieza Cantidad Referencia GE Appliances GXSHC40N 0110 WS03X10011 SELLADO, ANILLO O DE 1.125 X 1.37 0111 WS19X10005 SOPORTE, PANTALLA 0112 WS03X10013 PANTALLA 0113 WS22X10036 TAPÓN DE FLUJO, 15 GPM...
  • Page 80: Garantía (Ee.uu.)

    Si el producto se encuentra en un área donde no se encuentra disponible un Proveedor Autorizado de Servicio Técnico de GE Appliances, usted será responsable por el costo de un viaje o se podrá requerir que traiga el producto a una Ubicación del Servicio Técnico de GE Appliances Autorizado para recibir el servicio. En Alaska, la garantía excluye el costo de envío o llamadas del servicio a su hogar.
  • Page 81: Garantía (Canadá)

    Desde la fecha de compra en los materiales o la fabricación. Durante esta garantía limitada de un año, original. GE también proveerá, sin costo, todo el trabajo y el servicio relacionado con el reemplazo de la parte que presente defectos. Tres Años El monitor electrónico, si fallara debido a un defecto en los materiales o...
  • Page 82 Todas las ventas en Iowa requieren la siguiente firma antes de la consumación de la venta. Estas firmas deberán ser conservadas por el vendedor/ arrendatario por un mínimo de 2 años Comprador/ Arrendatario _____________________________________ Fecha ______________ Vendedor _________________________________________________ Fecha ______________ Domicilio del Vendedor __________________________________________________________ Nº Telefónico del Vendedor ______________________________________________________ Model GXSHC40N...
  • Page 83 Notas...
  • Page 84: Soporte Para El Consumidor

    En EE.UU.: GEAppliances.com/register Servicio Programado El servicio de reparación de expertos de GE Appliances está a sólo un paso de su puerta. Conéctese a través de Internet y programe su servicio a su conveniencia cualquier día del año. En EE.UU.: GEAppliances.com/ service o comuníquese al 800.432.2737 durante el horario de atención comercial.