Timer Operation; Adjustment Of Wind Direction - Toshiba RAV-SM564UTP Series Owner's Manual

Indoor unit
Table of Contents

Advertisement

Available languages

Available languages

5

Timer operation

Three timer modes are available: (Setting of up to 168 hours is enabled.)
Off timer
: The unit stops when the set time is reached.
Repeat Off timer
: The unit stops daily when the set time is reached.
On timer
: The unit starts when the set time is reached.
1
3
Set
1
Push
button.
The timer mode changes with every push of the button.
Off
Off
On
(Off timer)
(Repeat Off timer)
(On timer)
No display
and timer display flashes.
2
Push
to select "set time".
With every push of
button, the set time increases
by 0.5 hr (30 minutes).
When setting a time more than 24 hours for timer
operation, timer can be set in increments of 1 hr.
The maximum set time is 168 hr (7 days).
The remote control displays the set time with time
(between 0.5 and 23.5 hours) (*
1
) or number of days
and time (24 hours or more) (*
2
) as shown below.
With every push of
button, the set time decreases
by 0.5 hr (30 minutes) (0.5 - 23.5 hours) or 1 hr (24 -
168 hours).
Example of remote control display
23.5 hours (*
1
)
2
34 hours (*
)
Number of days Time
shows 1 day (24 hours).
shows 10 hours. (Total 34 hours)
15-EN
1115350203 EN TH.indb 8
1115350203 EN TH.indb 8
2
4
3
Push
button.
icon disappears and time display goes on,
and
or
icon flashes.
(When On timer is activated, time and On timer
are icons and other icons disappear.)
4
Cancel timer operation
Push
button.
Timer icon disappears.
NOTE
When the operation stops after the timer reached the preset
time, the Repeat Off timer resumes the operation by
pushing
button and stops the operation after the
time of the timer has reached the set time.
When
is pushed while the Off timer function of the
air conditioner is active, the indication of the timer function
disappears and then appears again after about 5
seconds.
This is due to normal processing of the remote controller.
6

Adjustment of wind direction

For best cooling and heating performance, adjust the louvers (adjustment plates of up / down wind direction)
appropriately. Cold air descends and warm air rises, so to heat a room tilt the louvers downward, and to cool a
room tilt them horizontally.
CAUTION
Direct the louvers horizontally for cooling.
If the louvers stay pointed downward when cooling, condensation may form on the discharge port and / then drops from
the louvers.
NOTE
If the louvers stay pointed straight out horizontally when heating, the room temperature may be unevenly
distributed.
For cooling (COOL)
Direct the louvers horizontally.
When the air conditioner is not working, the louvers are directed horizontally automatically.
The louvers are directed horizontally when heating begins, during defrost operation, or during the minimum
operation after reaching the set temperature.
When a swing or louver direction setting is made at this time, the remote controller display varies with the setting,
but the louvers stay pointed straight out horizontally.
When the air conditioner starts heating, the louvers are directed to the set direction.
– 8 –
For heating (HEAT)
Direct the louvers downward.
EN
ID
16-EN
03/27/14 9:47 AM
03/27/14 9:47 AM

Advertisement

Table of Contents
loading

Table of Contents