Specifications; Qualified Installing Agency; Product Features; Local Codes - Procom FBNSD32RT Owner's Operation And Installation Manual

Vent-free gas fireplace insert
Table of Contents

Advertisement

Inlet Gas Pressure* (inches of water)
(*for purposes of input adjustment)
Only a qualified agency should install and
replace gas piping, gas utilization equipment
or accessories, and repair and equipment ser-
vicing. The term "qualified agency" means any
individual, firm, corporation, or company that
either in person or through a representative
is engaged in and is responsible for:
SAFETY PILOT
This heater has a pilot with an Oxygen
Depletion Sensing (ODS) safety shutoff
system. The ODS/pilot shuts off the heater if
there is not enough fresh air.
PIEZO IGNITION SYSTEM
This heater is equipped with an electronic
piezo control system. This system requires
one AAA battery (provided).
Install and use heater with care. Follow all
local codes. In the absence of local codes,
use the latest edition of The National Fuel
Gas Code, ANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
25 West 43rd Street
New York, NY 10036
National Fire Protection Association, Inc.
1 Batterymarch Park
Quincy, MA 02269-9101
This heater is designed for vent-free operation.
State and local codes in some areas prohibit
the use of vent-free heaters.
200241-01E

SPECIFICATIONS

Model FBNSD32RT
Gas Type
Input Rating
Pressure Regulator Setting
Heater Dimensions (HxWxD) • 33.27" × 36.38" × 18.38"
Carton Dimensions (HxWxD) • 35.85" × 40.19" × 20.49"
Stove Weight • 88.2 lbs
Shipping Weight • 98.5 lbs

QUALIFIED INSTALLING AGENCY

PRODUCT FEATURES

LOCAL CODES

www.usaprocom.com
Natural Gas
Ignition
Piezo Ignitor
32,000 Btu/Hr
4" W.C.
Maximum 9.5"
Minimum 5"
a) Installing, testing, or replacing gas piping
or
b) Connecting, installing, testing, repairing, or
servicing equipment; that is experienced in
such work; that is familiar with all precautions
required; and that has complied with all the
requirement of the authority having jurisdiction.
2 GAS OPTIONS AVAILABLE
Your heater is equipped to operate on either
propane or natural gas. The heater is shipped
from the factory ready for connecting to
propane. The heater can easily be changed
to natural gas by having your qualified installer
follow the instructions on page 10 and the
markings on the heater.
State of Massachusetts: The installation
must be made by a licensed plumber or gas
fitter in the Commonwealth of Massachusetts.
Sellers of unvented propane or natural
gas-fired supplemental room heaters shall
provide to each purchaser a copy of 527
CMR 30 upon sale of the unit.
In the State of Massachusetts the gas
cock must be a T-handle type. The State
of Massachusetts requires that a flexible
appliance connector cannot exceed three
feet in length.
Propane Gas
Piezo Ignitor
32,000 Btu/Hr
9" W.C.
Maximum 14"
Minimum 11"
5

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FBNSD32RT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents