1.2 Description
Rated for Reliability in Harsh Environments
Power Supply
1.2

Description

The RUGGEDCOM RS930L features various ports, controls and indicator LEDs on the
front panel for connecting, configuring and troubleshooting the device.
2
Automatically selects fastest data rate based on distance and quality of cable
Software selectable to be master or slave
Frequency Division Multiplexing (FDM)
Immunity to EMI and heavy electrical surges
Hazardous Location Certification: Class I Division 2
-40 to 85 °C (-40 to 185 °F) ambient operating temperature (no fans)
20 AWG Galvanized Steel
DIN or panel mounting options provide secure mechanical reliability
[Optional] Conformal coated printed circuit boards
Fully integrated power supply
Universal high-voltage range:
125-250 VDC or 100-240 VAC (Hazardous Environments)
88-300 VDC or 85-264 VAC (Non-Hazardous Environments)
Terminal blocks for reliable maintenance free connections
CSA/UL 62368-1 safety approved to 85 °C (185 °F)