Maintenance, Care, Cleaning; Cleaning Condenser Coil - True Manufacturing Company TGU-2-HC Installation Manual

Table of Contents

Advertisement

TRUE
/
tcr
tcf

MAINTENANCE, CARE, CLEANING

CLEANING THE CONDENSER COIL
When using electrical appliances, basic safety precautions should be
followed, including the following:
TOOLS REQUIRED
Phillips Screwdriver
Stiff Bristle Brush
Adjustable Wrench
STEP 1 - Disconnect power to unit.
STEP 2 - Remove the four Phillips screws to allow removal of the
front grill.
STEP 3 - Remove bolts anchoring compressor assembly to frame
rails and carefully slide out. (Tube connections are flexible)
STEP 4 - Clean off accumulated dirt from condensing coil with a
stiff bristle brush.
STEP 5 - Lift cardboard cover above fan at plastic plugs and carefully
clean condenser coil and fan blades.
STEP 6 - After brushing condenser coil vacuum dirt from coil, and
interior floor.
STEP 7 - Replace cardboard cover. Carefully slide compressor
assembly back into position and replace bolts.
STEP 8 - Reinstall louver assembly onto unit with appropriate
fasteners and clips. Tighten all screws.
STEP 9 - Connect unit to power and check to see if condenser is
running.
17