Rinnai RHFE-951ETR Installation Manual page 7

Power flued flamefire space heater co-axial flue system
Hide thumbs Also See for RHFE-951ETR:
Table of Contents

Advertisement

• DIRECT EXTENDED
• UNDER FLOOR
NOTE
• SIDEWAYS
Total flue length may be up to 6.5 metres with 2 x 90° bends when going straight out of the back of the appliance. A maximum flue
length of 8.5 metres x zero bends is permissible provided no bend is used in the flue transition connection. Note: The aluminium
flue transition connection may contain one bend and this is counted as 1 (one) x 90° bend.
IMPORTANT
Rinnai
INSTALLATION CONFIGURATIONS
• DIRECT EXTENDED
• EXTERNAL WALL
• INTERNAL WALL
NOTE
7
• DIRECT
When cutting the flue transition for
joining to other components the
minimum total length is not to be
less than 300mm!
DIRECT
When cutting the flue transition for
joining to other components the
minimum total length is not to be
less than 300mm!
EXTERNAL
DIRECT
WALL
EXTENDED
SIDEWAYS
POWER FLUED FLAMEFIRE FIM