Rinnai RHFE-752ETR Operation & Installation Manual
Rinnai RHFE-752ETR Operation & Installation Manual

Rinnai RHFE-752ETR Operation & Installation Manual

Power flued flamefire gas space heater
Hide thumbs Also See for RHFE-752ETR:
Table of Contents

Advertisement

Quick Links

Power Flued Flamefire
Gas Space Heater
RHFE-752ETR
This appliance shall be installed in accordance with:
• Manufacturer's Installation Instructions
• Current AS/NZS 3000 & AS/NZS 5601
• Local Regulations and Municipal Building Codes
This appliance must be installed, serviced and repaired by an Authorised Person.
All Rinnai gas products
are A.G.A. certified.

Advertisement

Table of Contents
loading

Summary of Contents for Rinnai RHFE-752ETR

  • Page 1 This appliance shall be installed in accordance with: • Manufacturer’s Installation Instructions • Current AS/NZS 3000 & AS/NZS 5601 • Local Regulations and Municipal Building Codes This appliance must be installed, serviced and repaired by an Authorised Person. All Rinnai gas products are A.G.A. certified.
  • Page 2 Congratulations on the purchase of your Rinnai RHFE-752ETR Flamefire. We trust you will have many years of comfort and enjoyment from your appliance. BEFORE PROCEEDING WITH THE OPERATION OR INSTALLATION OF YOUR NEW HEATER PLEASE READ THIS MANUAL THOROUGHLY AND GAIN A FULL UNDERSTANDING OF THE REQUIREMENTS, FEATURES AND OPERATION OF YOUR NEW APPLIANCE.
  • Page 3 Mobile Phone: _____________________________________________________ Certificate of Compliance / Certification Number: ______________________________ Authorised Persons - Licence Number: _______________________________________ Installers Signature: _____________________________________________________ Installation Date: _____________________________________________________ APPLIANCE DETAILS Model Number: _____________________________________________________ Serial Number: _____________________________________________________ Installation Address: _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ Rinnai Australia Operation Manual...
  • Page 4: Table Of Contents

    INSTALLATION REQUIREMENTS ....................1 CERTIFICATION .......................... 1 FLUE INSTALLATION MANUAL ....................1 CARTON CONTENTS / ITEM CHECKLIST ................. 1 ABOUT YOUR NEW RHFE-752ETR SPACE HEATER ..........2 GENERAL DESIGN LAYOUT ...................... 2 REMOTE CONTROL GENERAL LAYOUT .................. 3 REMOTE CONTROL DISPLAY....................4 FEATURES...........................
  • Page 5: Before You Start

    Please keep these instructions in a safe place for future reference. FLUE INSTALLATION MANUAL These instructions are to be used in conjuction with the Rinnai “Power Flued Flamefire Space Heater Co-axial Flue System Installation Manual” supplied with flue kits ASPDFK or ASPKIT03.
  • Page 6: About Your New Rhfe-752Etr Space Heater

    ABOUT YOUR NEW RHFE-752ETR SPACE HEATER GENERAL DESIGN LAYOUT AUTO OVERHEAT DOUBLE GLAZED ROOM AIR RETURN DISCHARGE VENT FLAME WINDOW RECEIVER WINDOW / BLOCKAGE INDICATOR LOUVRE, WARM BURNER MEDIA Remote control receiver, Indicator AIR DISCHARGE for filter/louvre blockages CONTROL PANEL...
  • Page 7: Remote Control General Layout

    ABOUT YOUR NEW RHFE-752ETR SPACE HEATER REMOTE CONTROL GENERAL LAYOUT FRONT REAR STANDBY / ON BUTTON Stops and Operates the heater remotely. Lock Override Extra Low Flame CONTROL BUTTONS Used to select the temperature, Temperature Time flame picture and adjust timers.
  • Page 8: Remote Control Display

    ABOUT YOUR NEW RHFE-752ETR SPACE HEATER REMOTE CONTROL DISPLAY MAIN DISPLAY OVERRIDE INDICATOR Displays current Clock, Timer or Displays when Override has been Temperature status. selected. MAIN DISPLAY MODE EXTRA LOW INDICATOR Indicates that controller is in Time Displays when Extra Low function or Temperature display modes.
  • Page 9: Safety

    Young children should be supervised to ensure they do not play with the appliance. g. If the supply cord is damaged or requires replacing, it must be replaced by the manufacturer or the manufacturer's agent or similarly qualified person in order to avoid a hazard. Rinnai Operation Manual...
  • Page 10 This effect may be amplified if the air in the room contains cooking vapours or cigarette smoke. To avoid this possibility, it is recommended that a mat be placed in front of the appliance, extending at least 750 mm in front of it. Rinnai Operation Manual...
  • Page 11: Basic Heater Operation

    NOTE To re-activate the remote control press any button on the keypad. This returns the display to the previous mode. No information is transmitted from the controller to the heater when re-activating the display. Rinnai Operation Manual...
  • Page 12: Turning On The Power

    Timer 1 Set ON OFF Timer 2 Set ON OFF B. 16°C ~ 26°C (in 1°C steps) – Thermostatic control to pre-set temperature selected. Combustion rate varies to maintain the selected temperature. C. H (High) – Continuous combustion on high. Rinnai Operation Manual...
  • Page 13: Flame Function

    To replace batteries simply unscrew the battery compartment cover located on the back of the remote control anti-clockwise. When installing new batteries ensure that the correct polarity is observed, the polarity is engraved into the battery compartment. See the illustration on page 3. Rinnai Operation Manual...
  • Page 14: Programmed Heater Operation

    6:00 6:30 7:00 before the programmed ON time the micro-computer will ignite the burner. Room Average Timer temperature ignition programmed sensed ON time Earlier than Later than usual ignition usual ignition Rinnai Operation Manual...
  • Page 15: Using The Timers

    Time Timer 1 Set ON OFF The Remote Control Display will show "Lock" in the top left hand Timer 2 Set ON OFF corner. To cancel the Lock function hold down the Lock button for 3 seconds. Rinnai Operation Manual...
  • Page 16: Care And Maintenance

    When an obstruction is detected the Blockage Indicator LED which is located above the Receiver Window will illuminate RED and the combustion state reduces to front burner, low operation only. To restore normal operation remove the obstruction and use the remote control to resume normal heater operation Rinnai Operation Manual...
  • Page 17: General Heater Characteristics

    If the power supply cord or any other component of the heater are damaged, they must be replaced by Rinnai or a suitably qualified person. Any service or repair work should only be carried out by an authorised person. Rinnai has service and spare parts departments nationally, see back cover for contact details.
  • Page 18: Trouble Shooting Checklist

    CARE AND MAINTENANCE TROUBLE SHOOTING CHECKLIST Use the following chart to help determine whether a service call is required, however if you are unsure about the way your heater is operating, contact Rinnai or your local agent. Fault Condition Possible Remedy...
  • Page 19: Installation Manual

    8. COMMISSIONING ......................25 9. SETTING AIR GUIDE VANES (AIR FLOW CONTROL) ............ 25 10. INSTALLING THE FASCIA PANEL ................26 11. INSTALLATION AND COMMISSIONING CHECKLIST ........... 26 12. FINAL CHECKLIST ......................26 TECHNICAL INFORMATION ..................27 WIRING DIAGRAM ........................27 Rinnai Installation Manual...
  • Page 20: Installation General

    INSTALLATION GENERAL PRODUCT SPECIFICATIONS Model: RHFE-752ETR General description: Inbuilt, glass or steel fronted, ceramic log space heater with forced convection heating and power flue system. Gas input rate: Natural Gas Propane Low (MJ/hr): High, Extended flue / Direct flue (MJ/hr): 28 / 31.5...
  • Page 21: Heater Location

    In some cases curtains may need restraining. ENCLOSURE REQUIREMENTS As the Rinnai RHFE-752ETR has a cool outer casing it can be installed into existing Masonry fireplace or into a decorative fireplace constructed from combustible materials such as wood or plaster.
  • Page 22: Gas Supply

    This heater has a power cord with a three pin plug supplied. The power cord passes through a slot in the lower right of the appliance. If a left hand entry is required contact Rinnai for details. Rinnai recommend the heater be plugged into a 240V, 10A earthed power point.
  • Page 23: Flue Installation

    FLUE INSTALLATION TYPES OF FLUE INSTALLATIONS Consult the Rinnai “Power Flued Flamefire Space Heater Co-axial Flue System Installation Manual” supplied with flue kits ASPDFK or ASPKIT03 for detailed flue installation instructions. Use only Rinnai RHFE-752ETR flue components with this appliance.
  • Page 24: Flue Terminal Location

    FLUE INSTALLATION FLUE TERMINAL LOCATION The flue terminal should be positioned away from flammable materials. The RHFE-752ETR flue terminal is ‘Fan Assisted’ with a maximum input WARNING of 32 MJ/h Ensure that the location of the flue terminal can comply with the requirements of AS/NZS 5601 - Fig.
  • Page 25: Heater Installation

    Remove the heater body assembly from the engine carton and position in front of the enclosure opening. The heater does not come supplied with flue components. These are purchased separately. ONLY Rinnai RHFE-752ETR flue components can be used with this appliance. NOTE 2. CONNECTING THE APPLIANCE TO THE CONSUMER PIPING 240 VOLTS, RISK OF ELECTRICAL SHOCK! Isolate the electricity supply before removing any panels.
  • Page 26: Heater Body Installation

    Secure heater body through these points using appropriate fixings. 5. CONNECTING THE FLUE SYSTEM TO THE APPLIANCE Only Rinnai RHFE-752ETR flue components MUST be used with this appliance. Connections between the heater and the flue system MUST BE made in accordance with the IMPORTANT Rinnai “Power Flued Flamefire Space Heater Co-axial Flue System Installation Manual”...
  • Page 27: Installing Burner Media

    DO NOT place the burner media above the level of glass retaining wall and avoid gaps. DO NOT place ANY burner media onto the burner plates. Place burner media evenly and AVOID any large gaps between the burner media. Rinnai Installation Manual...
  • Page 28 DO NOT place the burner media above the level of glass retaining wall and avoid gaps. DO NOT place ANY burner media onto the burner plates. Place burner media evenly and AVOID any large gaps between the burner media. Rinnai Installation Manual...
  • Page 29: Commissioning

    DO NOT attempt to adjust the air flow direction while the appliance is in operation or hot as CAUTION this can result in burn injury. The horizontal louvres (which direct vertical air flow) are fixed and cannot be adjusted. Rinnai Installation Manual...
  • Page 30: Installing The Fascia Panel

    1. Appliance positioned in a suitable location (clearances, combustible clearances, mantels and surrounds etc). 2. Is a Rinnai approved flue system installed & tested in accordance with the instructions? 3. Gas pressure checked and set? 4. Has the burner media been installed as per instructions? 5.
  • Page 31: Technical Information

    F (3A) gr/y R.TH AC 230-240V gr/y 6 5 4 4 3 2 1 3 2 1 bl w y bk pl gy or y or bk bk y bk br bl w 8 6 3 4 1 Rinnai Installation Manual...
  • Page 32: Contact Information

    Tel: (03) 9271 6625 Fax: (03) 9271 6622 Rinnai has a Service and Spare Parts network with personnel who are fully trained and equipped to give the best service on your Rinnai appliance. If your appliance requires service, please call our National Help Service Line. Rinnai recommends that this appliance be serviced every 2 years.

Table of Contents