Installation Clearances; Model Number Identification - Lennox 16HPX Series Unit Information

Table of Contents

Advertisement

Installation Clearances

See NOTES
See
NOTES
See NOTES

Model Number Identification

Nominal SEER
Unit Type
HP = Heat Pump
Refrigerant
X = R-410A
Regional Standards
– (dash) = All Regions
See
NOTES
CONTROL
BOX
16 HP X – 036 - 230 A 0 1
Page 2
NOTES:
Service clearance of 30 in. (762 mm) must be maintained on
one of the sides adjacent to the control box.
Clearance to one of the other three sides must be
36 in. (914 mm)
Clearance to one of the remaining two sides may be
A clearance of 24 in. must be maintained between two units.
48 in. (1219 mm) clearance required on top of unit.
Voltage
230 = 208/230V-1phase-60hz
Nominal Cooling Capacity
024 = 2 tons
036 = 3 tons
048 = 4 tons
060 = 5 tons
Revision Number
Ratings Revision Level

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

16hpx-02416hpx-03616hpx-04816hpx-060