Technical Data:
Operating voltage:
Battery type:
Sensor type:
Product life:
Sensitivity adjustment:
Standby current:
Alarm current:
Alarm Volume:
Temperature range and humidity:
Disposal note:
This product may not be disposed of with household waste. At the end of its useful life, the product must be
returned to a point of acceptance for the recycling of electric and electronic device. Please ask your local
municipality for the point of acceptance! As the devices contain valuable recyclable materials, they should be sent
for recycling, in order not to harm the environment or human health from uncontrolled waste disposal.
Proper disposal of batteries and accumulators:
Batteries and rechargeable batteries may not be disposed in the household waste. The end-consumer are legally
obligated to the return of all used batteries and/or accumulators. After usage you can return batteries and / or
accumulators gratuitous in the sales point or in their direct vicinity (for example at municipal collection points and
trade). Otherwise, you can also return the batteries and / or accumulators by post to us.
3 x 1,5V DC
AA LR6
electrochemical
10 years after production date
Complies EN 50291-1: 2018 standard:
Alarm mode for low CO concentration:
Red LED (ALARM) flashes 4 times in succession and the alarm
sounds (slower than in alarm mode) every 3-5 minutes:
>30PPM: Alarm at the same or higher CO concentration for longer
than 60 minutes
>40PPM: Alarm at the same or higher CO concentration for longer
than 40 minutes
Alarm mode for increased to dangerously high CO concentration:
Red LED (ALARM) flashes and beeps 5 times in succession 3
times at 10 second intervals:
>27±3 PPM: Alarm at the same or higher CO concentration for
longer than 120 minutes
>55+5 PPM: Alarm at the same or higher CO concentration for
longer than 60 to 90 minutes
>110±10 PPM: Alarm at the same or higher CO concentration for
longer than 10 to 40 minutes
>300±30 PPM: Alarm at the same or higher CO concentration for
longer than 3 minutes
<30μA
<65mA
≥ 85dB (A) within 3m
-10°C – +45°C/ 0-93%