• Length - The maximum fiber optic cable length is 2 km (6558
feet), if system budgets are met. However, IEEE 802.3 FOIRL
(Fiber Optic Inter-Repeater Link) specifications specify a
maximum of 1 km (3279 feet).

3.3.2 Fiber Optic Interface (Fiber Optic Ports)

Ex040 and Ex040-X:
Parameter
Receive
Sensitivity:
Peak Input
Power:
Transmitter Power:
50/125 m fiber: -13.0 dBm -15.0 dBm
62.5/125 m fiber: -10.0 dBm -12.0 dBm
100/140 m fiber: -7.0 dBm
Error Rate:
NOTE: The transmitter power levels and receive sensitivity levels given
above are Peak Power Levels after optical overshoot. A Peak Power Meter
must be used to correctly compare the values given above to those
measured on any port. If Power Levels are measured with an Average
Power Meter, add 3 dBm to the average power measurement to correctly
compare average power values to the peak power values.
Page 3-8
ST fiber optic ports
Typical
Worst
Value
Case
-30.5 dBm -28.0 dBm
-7.6 dBm
-8.2 dBm
-9.0 dBm
Better than 10
Worst
Typical
Case
Budget
Budget
13.0 dB
17.5 dB
16.0 dB
20.5 dB
19.0 dB
23.5 dB
-10
bit error rate.